Installation, Operation – Pyromation Precision Tip Re-Adjustable Melt Bolt Thermocouple User Manual

Page 2

Advertising
background image

INSTALLATION

B

2 3/4" - 3 3/4"

X

0" - 1"

ADJUSTABLE

1/2" - 20 2A UNF

1/8" GRADUATED MARKINGS

05/32"

3/4" HEX

Removing existing sensor using the following steps:

1. Retract existing sensor to minimum immersion.

2. Allow machine to cool and return to an un-pressurized condition.

3. Remove sensor from machine.

4. Inspect mounting hole to ensure there is no debris or deterioration

of the sealing surface and threads. See Figure 2 below.

Clean and repair as needed.

Install the new sensor using the following steps:

1. Retract the new sensor to minimum immersion.

2. Install sensor into mounting hole.

3. Tighten sensor into machine using the 3/4” hex to 40 foot/pounds.

4. Connect instrument extension leads.

1/2"-20 UNF, 2A
10 THREADS MINIMUM

00.312"-0.318"

0.100" MAX IMPERFECT THREADS

0.250"

31 to 45

OPERATION

The Melt Bolt should be fully retracted during operation start up. When the plastic

reaches a melted state, the melt bolt can be immersed. Turn the adjusting screw

clockwise to extend the tip, turn the screw counter-clockwise to retract the tip. The

graduated markings are spaced at 1/8” intervals allowing for easy repeat sensor

placement. Retract the melt bolt completely before allowing the melt stream to

cool. Forcing the screw may result in damage to the sensor.

Figure 1

Figure 2

Phone (260) 484-2580 • FAX (260) 482-6805 or (800) 837-6805 • www.pyromation.com

2 of 2

Melt-1

© Copyright 2005 Pyromation, Inc., All Rights Reserved.

Advertising