3.2 EXTERNAL INPUT

It connects to an external sensor.

ALARM/MD -> EXT

• EXT-IN - OPEN : COLOR / ALARM OFF

- CLOSED : B/W / ALARM ON






3.3 EXTERNAL OUTPUT

The EXT-OUT lead and MD-OUT lead output voltage is different according to D/N and
MD settings. Please refer to below in detail.

1. EXT-OUT output voltage

The EXT-OUT lead output voltage for
COLOR and B/W is as following.

• EXT-OUT - COLOR : 0V

- B/W : 5V

2. MD-OUT output voltage

The MD-OUT lead output voltage is as

following in case MD event occurs

when 'ALARM/MD MENU' -> 'MODE' is set

to MD, MD+EXT

• MD-OUT - MD OFF : 0V

- MD ON : 3.3V

3.4 RS-485 CONNECTION

Connecting to the RS-485 : The Camera can be
controlled remotely by an external device or
control system, such as a control keyboard,
using RS-485 half-duplex. Connect Market Rx+,
Rx- to Tx+ and Tx- of the RS-485 control system.