0 appendix, 2 typical system installations – Rola-Chem 554230 ORP Digital Controller User Manual

Page 12

Advertising
background image

7.0 Appendix

7.1 WATER CHEMISTRY RANGES

(These ranges are in accordance with suggested NSPI
Standards for swimming pools.)

pH: 7.4 -7.6

Alkalinity: Approx. 80-120 ppm ** (parts per million)
Higher levels may be acceptable in areas where it naturally
occurs in the local water supply.
Consult a pool professional in your area.
Cyanuric Acid:
0-50 ppm.

(Maintain at 30 ppm or less for best probe life.)*

TDS (Total Dissolved Solids): 300 - 2000 ppm
Calcium Hardness: 200-400 ppm
Free Chlorine:
1.0 - 3.0 ppm (> 700 millivolts ORP)

*20-30 ppm of cyanuric acid provides approx. 95% of the shielding effect for
chlorine.

**When using tri-chlor, recommended alkalinity is 95-125 ppm.

7.2 Typical System Installations

FILTER

**SAFETY FLOWSWITCH TO ENSURE
CIRCULATION TO CONTROL PROBES
AND INDICATOR THAT POOL
CIRCULATION IS OCCURRING.

*SAFETY FLOWSWITCH FOR

PROTECTION OF HEATER AND

TO ENSURE DILUTION OF
CHEMICAL INTO POOL.

*** OPTIONAL FILTER TO

HELP KEEP MANIFOLD

AND PROBES CLEAR OF

DEBRIS.

SYSTEM USING CHLORINE

EARTH
GROUND

MANUAL pH CONTROL

POOL
PUMP

WATER

FROM
POOL

EARTH
GROUND

*FLOWSWITCH

WATER
TO

POOL

ORP

CONTROLLER

PUMP

***FILTER

HEATER

**FLOWSWITCH

ELECTRICAL
OUTLET
CONTROLLED BY
CIRCULATION
SYSTEM

MANIFOLD

CHLORINE

Rola-Chem Digital Controller PN 554226 6/01/2012 Page: 12 of 12