Rola-Chem 554230 ORP Digital Controller User Manual

Page 7

Advertising
background image

• To turn the controller “OFF” press MODE so the AUTO light is off and hold

the MODE button for two seconds until the ORP displays read “OFF”.

Release the MODE button, the controller turns off and the display goes blank.
Note: Turning the controller “OFF” using the MODE button simply turns off the
controller functions, but does not turn off the power to the controller. The FLOW
lamp is both the power light and a flow indicator when flow switch is used.

• When Flow light is on and Auto light is off, levels can be set.

Set level button: Pressing the set level button once will display the current set level.

To change the set level, press the set level button until the desired level is
reached.


Feed time: The feed times are displayed in seconds.

Each feed cycle includes a five (5) minute delay time. Pressing the feed time
button allows the user to select available feed times. Release the button when
the desired ORP feed time is reached.
To set the controller in constant feed, release the button when the display
reads “con”.

AUTO mode: This is normal operation mode. The controller operates the feeder to

automatically maintain the parameters set for ORP.

3.0 Installation

3.1 Locating the controller

Install the chemical pump/ feed systems as shown in manuals included with the
feeders. Before installing the controller, it is important to do a site assessment to
consider where and how you will mount the unit. The controller should be
mounted on a wall or other surface within eight feet of the feeder, at least ten
feet away from the edge of the water, and within six feet of the GFCI power
source. Never mount a controller above or near an acid tank.

See appendix for

typical feed system schematics.

3.2 Mechanical Installation

Once the site is selected, obtain screws or anchors

to securely mount the

controller on the wall or a panel.


Screw slots are provided in the controller enclosure. Access to flow switch
wires, acid/base changes and terminals is located on the back of the enclosure.



Rola-Chem Digital Controller PN 554226 6/01/2012 Page: 7 of 12