There are three mounting configurations for a DL75: Me-
chanical Meter (DL75M), Insertion Magmeter (DL75ME),
and Wall (DL75W). The meter mount models match up to
any SeaMetrics lower square housing. All configurations can
be factory-ordered or field-installed. Converting from one
mounting configuration to another requires use of MK10 or
MK20 mounting kits.

Meter Mounting. Remove the four screws on the meter
cover with a 5/32” Allen wrench. After connecting the leads
to their respective terminals (see diagram), put the DL75
in place of the meter cover and tighten the screws evenly.
The gasket on the DL75 should be visibly compressed by
tightening all around.

MOunTinG and cOnnEcTiOnS

2.82”

3.95”
4.52”

3.35”

2.06”

3.95”

DL75

Data Logger

Data

Port

Active
Replace

Battery

4.90”

3”

16

DL75W (WALL MOunT)

DiMEnSiOnS

DL75M (METER MOunT)

BATTERY

DL75 TO inSERTiOn MAGMETER

cOnnEcTiOnS (see also next page)

Magmeter

Terminal Block

+

S

-

+ -

+ -

caution: Do not apply external
power to the DL75.

DL75 TO MEchAnicAL METER

SeaMetrics FlowInspector software is required for operation
of the DL75. Please consult your FlowInspector manual for
instructions in loading the software onto your computer,

setting up your DL75 for use, downloading, storing, and
analyzing your data.