Ar ch ive d – Seametrics TX100-200-SERIES v.1 User Manual

Page 3

Advertising
background image

Rotor

Rugged cast aluminum housing

18 Foot Cable

Modular electronics (optional)

• rate/total/pulse/4-20 mA

• blind 4-20 transmitter

• pulse divider

Compression nut

for easy adjustment, secure locking

Adapter fitting

with 1-1/2” NPT threads

Rotor housing

Removable jewel bearings

TX101/201

Adapter fitting

with 2” NPT threads

Full-port 2” ball valve

for sensor removal

2” Adapter

removes to mount

hot-tap machine

3/4” diameter tubing

for low insertion force

TX115/215

Locking collar

TaBlES aND DIaGRaMS

Page 1

GENERal INfORMaTION

The TX100/200-Series are adjustable depth insertion turbines

that come in brass or 316 stainless models to fit 3” to 48”

pipe. Installation fittings are standard 1-1/2" (101/201) or 2”

(115/215) FNPT. Fittings such as saddles and weldolets may

be purchased either locally or from Seametrics.

Ruby bearings and a non-drag pickoff give these adjustable

insertion turbine flow sensors a wide flow range and long life.

A sensor detects the passage of miniature magnets in the ro-

tor blades. The resulting square-wave signal can be sent for

hundreds of feet without a transmitter, over unshielded cable.

This signal can be connected directly to many PLC’s and other

controls without any additional electronics.

If desired, a modular system of electronics can be installed ­­­­

directly on the flow sensor or mounted remotely. The FT415

(battery powered) or FT420 (loop powered) provides digital rate

and total display, as well as programmable pulse; the FT420

also provides a 4-20 mA analog output. The AO55 is a blind

analog (4-20 mA) transmitter. Programmable pulse for pump

pacing is available with the PD10.

The “hot-tap” models (TX115/215) can be installed or serviced

without shutting down the line by means of a 2” full-port isola-

tion valve that comes with a nipple for installation on the pipe

fitting. In most circumstances, no special tool is required.

fEaTURES

SPEcIfIcaTIONS*

Standard

Micropowered (-04 Option)

6-40 Vdc/< 2 mA

3.5-16 Vdc/60 µA @ 3.5 Vdc

Magnetoresistive

Magnetoresistive

­­­­

Current Sinking Pulse

Current Sinking Pulse

100 mA max

2 mA max

3-40 Vdc

≤ Supply Voltage

TX101/115

TX201/215

3” - 12” (50 - 300mm)

12” - 35” (300 - 890mm)

Cast aluminum

Brass or 316 SS

PVDF standard

Nickel-bound tungsten carbide/Ruby

­­­­

TX101/201

­­­­

TX115/215

None

Bronze (316SS optional)

1-1/2” NPT

2” NPT

­­­­

­­­­

0.5 - 30 feet/sec (0.15 - 9.14 meter/sec)

+/-1.5% of full scale

200˚ F (93˚ C)
200 psi (14 bar)

0.44 x pressure in pipe

#22 AWG 3-con, 18’ (6m); 2,000’ (650m) maximum cable run

Mark (Standard Power Only)

Power Source

Supply Voltage/current

Sensor

Type

Output

Sinking current

External Pull-up Resistor

Pipe Size

Materials Housing

Sensor Body

Rotor

Shaft/Bearings

Isolation Valve

fitting Size

flow Range

accuracy

Maximum Temperature

Maximum Pressure

Insertion force

cable

Regulatory

*Specifications subject to change. Please consult our website for the most current data (www.seametrics.com).

Note: For larger pipe sizes contact factory

AR

CH

IVE

D