Control interfaces, Defaults, Remote control connection – Audient ASP510 Surround Sound Controller User Manual

Page 7: Installation

Advertising
background image

Operation Manual

Installation

7

©audient 5/2001

CONTROL INTERFACES

The ASP510 allows various logic control

signals from the host mixing console to

be interfaced to allow continued operation

of console solos etc. These connections

are detailed on the next page and are made

via AC/DC floating opto-isolators that will

successfully detect any positive or negative

going control voltage between 2v and 24v.

Console solo and talkback systems differ

widely and the relevant manufacturer

should be consulted for details of suitable

ways of deriving logic output signals

interfacing to the ASP510.

REMOTE CONTROL

CONNECTION

The ASP510 Surround Processor rack unit

is connected to its remote control via a

standard CAT5 data cable which plugs into

the REMOTE socket on each unit. A 5m

cable is supplied with the unit but any non-

reversed CAT5 FTP (sheilded twisted pair)

cable may be used. The maximum

recommended length of cable is 20m

DEFAULTS

When you first turn on your ASP510 it will load the following default set-up:

MONITOR FORMAT:

5.1

ALTERNATE SPEAKERS:

OFF

STEREO RECORD SOURCE:

BUS

MONITOR SOURCE:

SURROUND RECORD

ENCODER/DECODER:

OUT

GUIDE:

OFF

REF:

OFF

REFERENCE LEVEL:

-10dB

VOLUME:

FULLY COUNTER-CLOCKWISE

DIM:

ON

DIM LEVEL:

-20dB

CUT:

CUT

MODE:

CUT

SPEAKERS:

ON

MONITOR TRIMS:

0dB

To restore these defaults hold down the Bypass button until it flashes and then

release it.