Wiring, Wiring 9 – Badger Meter 3-A Sanitary User Manual

Page 9

Advertising
background image

Wiring

Typical wiring configurations for the available pickup options are shown in

Figure 5

,

Figure 6

, and

Figure 7

Option Number

Description

Number of Pins

0

NEMA 6 – Magnetic

3

1

NEMA 6 – Magnetic (Amplified)

3

2

Non-NEMA 6 – Magnetic

2

3

Non-NEMA 6 – Magnetic (Amplified)

3

4

Non-NEMA 6 – Active (4…20 mA)

5

6

Non-NEMA 6 – Magnetic (High Temperature)

2

8

Non-NEMA 6 – Active (0…5V DC)

5

9

No Pickup

N/A

Table 3: Pickup options

Pickup Option 1

Braided Shield to

Earth Ground

3 - Red/White = Signal

2 - Red/Black = Power

1 - Green = Common

Mag Pickup

With Pre-Amp

(Socket End)

1. Common:

Power return

2. Power:

12…24 Vdc

3. Output Signal: 10V DC Square Wave

Pins

Pickup Option 0

Braided Shield to

Earth Ground

3 - Red/White = Unused

2 - Red/Black = Signal

1 - Green = Signal

Standard

Mag Pickup

(Socket End)

1. Signal

2. Signal

3. Unused

Pins

Figure 5: Wiring for NEMA 6 magnetic pickups

User Manual

Page 9

November 2013

Advertising