Totalizer Pulse Output (PulsOut)

Basic Function

The pulse output PulsOut parameter can be either Enabled or Disabled When enabled this output generates a fixed width 30

mS duration pulse every time the least significant digit of the totalizer increments The amplitude of the pulse is dependent

on the voltage level of the supply connected to the pulse output and is limited to a maximum 28V DC
The ER-500 provides two types of totalizer pulses The basic open drain FET output

provides a ground referenced output pulse

that swings between about 0 7V DC and V

CC

(See

Figure 13

)

JP1

JP2

JP3

P1

Freq. In

4-20mA

Iso Total Pluse

TR_B

TR_A

RS485 Gnd

Setpoint 1

Setpoint 2

Gnd

+

+

+

Total Reset

Total Pluse

Signal Gnd

Mag

Pulse

Iso

OC

Low

High

Input

Total P

ulse

Sig
nal

TB1

Open Drain FET

Total Pulse Output

2.2…10K

Pull-up

Resistor

V

CC

Internal

100 mA

Maximum

Figure 13: Open drain connections

The isolated pulse output (ISO),

Figure 14

, is again an open collector output with the emitter of the transistor connected to the

negative output terminal and is not referenced to ground This output is optically isolated from the input signal for systems

that require a totally isolated output pulse