Operation, Battery care and maintenance – Blue Angel Pumps BSM55 User Manual

Page 8

Advertising
background image

and then hang up. The internal 3-minute timer starts and

the System tallies and remembers the number of rings.
2. On your second call within “3” minutes, let the phone ring

until the System answers. The System will answer

first because it remembered the first “3” rings, and then

answers with an audible system status. If done properly, the

answering machine/voice mail will not answer.
HOW TO CANCEL ALARM PHONE CALLS FROM YOUR

SYSTEM
To cancel the alarm phone call from one of the numbers in the

phone call list:
To cancel a call out sequence from the System while listening to

an alarm message, do the following:
1. Answer the phone call.
2. Listen to the alarm message.
3. When told, press the number “1” key followed by the

pound (#) key within “1” minute to cancel the alarm call

out. You can cancel the call at anytime during the

message.
4. You can listen until you hear the System say goodbye

or just hang up the phone.
5. If you do not cancel the call, the system will call the next

number in your phone number list. The first cancel will

stop all calls for all numbers. This sequence will repeat

every 15 minutes until a call is cancelled.
To cancel the alarm phone call using the System display:
Press and hold the RESET button once to cancel the call (phone

icon is present) and the RESET up to 5 seconds if multiple

errors/alarms are present on the display to stop receiving phone

calls. You will then be required to also clear/reset the message(s)

on the display.

PLACE A PHONE CALL TO YOUR SYSTEM TO CANCEL AN

ALARM
To cancel a call out sequence during an active alarm condition,

do the following:
1. Make the call to the System (phone number at alarm

location)
2. Wait for the System to answer (5 or 10 rings Menu option

selectable)
3. Listen to the alarm message.
4. Press the number “1” key followed by the pound (#) key

anytime during the message to cancel the alarm call out

and then hang up the phone.
REMOTE STATUS CHECK
The System will answer incoming calls if a warning condition

exists on the display. When no alarm issue exists, you will get

a general status update. If the call out sequence has been

cancelled for an alarm by pressing "1" then "#" on the phone,

but the alarm condition still exists on the display, the System will

answer and describe the alarm condition.

CANCELING AN ALARM CALL OUT SEQUENCE WITH AN

ANSWERING MACHINE/VOICE MAIL DEVICE ON THE SAME

PHONE LINE
To cancel the alarm call out-sequence, do the following:
STEP ACTION
1. Make the call to the System (phone number at alarm

location).
2. Let the phone ring the desired number of times (before the

other in-line answering machine/voice mail can answer), Hang

the phone up.
3. Call the number a second time within three minutes (The

System keeps track of all the rings from the previous

calls, accumulates them until the total ring count matches its

ring count number, 5 or 10, and then it will answer). Listen to

the alarm message.
4. Press the number “1” key followed by the pound (#) key

anytime during the message to cancel the alarm call out. Hang

up the phone.

Operation

1. After installation, the back-up pump will start once the water

level raises the bottom float.

2. The System has a charging circuitry designed to optimize the

recharging time of your battery and to prevent overcharging.

In addition, the control box has a time delay which keeps the

pump from repeated, short cycles when it shuts off. This

time delay feature will allow the pump to run 15 seconds

after the switch reaches the off position.

3. MUTE FUNCTION: Press the mute button once to silence the

alarm for 12, 24, or 48 hours (menu selectable). To turn off the

mute timer, press and hold the RESET button down for 5

seconds.

1. Unplug the transformer.

2. For batteries with top caps that can be removed, the

electrolyte level should be checked and filled to

manufacturer’s specifications. The charge for each cell

should be checked with a hydrometer. A specific gravity of

1.265 indicates the battery is at full charge. If the specific

gravity of any of the cells varies more than .050, the battery

should be replaced.
3. If the battery fluid levels are low or battery plates are exposed,

refer to the manufacturer's recommendations on how to

replenish properly.
4. Inspect the terminals and clamps for corrosion and

tightness. Clean and tighten as required.

EXTENSION CORDS
We DO NOT recommend using extension cords, but if you find it

absolutely necessary then:
1. Use at least a 16 gauge cord that does not exceed 50 feet

in length.

Explosion hazard. Smoking

and open flames prohibited.

Battery recharging and connections MUST be performed

in a well ventilated area. Before servicing the batteries,

blow away the gases by waving a piece of cardboard near

the batteries.

Battery Care and Maintenance

If the System is set to answer in 10 rings (one of

the Menu selectable options), you will need to

place more calls within "3" minutes to get the System to eventually answer.

Canceling the call out sequence does not

cancel an active alarm. System will continue

to beep and the alarm message will be displayed on the digital display

until you hit reset for each message/condition. If you do not hit reset, each

alarm message on the display system will recall the phone number(s) in

the last 72 hours as a reminder for the uncleared alarm conditions.

An inexpensive hydrometer can be purchased at

an automotive parts dealer.

8

Operating Instructions and Parts Manual

www.blueangelpumps.com

Advertising