10. Secure the discharge line before

starting the pump. An unsecured
discharge line will whip, possibly
causing personal injury and/or
property damage.

11. Periodically inspect the pump

and system components. Perform
maintenance as required. If the
pump is idle for long periods
of time, add water to the basin
occasionally to start the pump.

12. Provide a means of pressure relief

for pumps whose discharge line can
be shutoff or obstructed.

13. Do not install the pump in any

location classifi ed as hazardous by
National Electric Code, ANSI/NFPA
70-1984.

14. Secure the pump in its operating

position so it cannot tip over, fall or
slide. Install this pump in the vertical
position only.

15. Make sure lifting handles are

securely fastened each time before
lifting. Do not operate pump
without safety devices in place.
Always replace safety devices that
have been removed during service
or repair. DO NOT LIFT PUMP BY
POWER CORD.

16. Do not run the pump dry. Dry

running can overheat the pump and
will void the warranty.

17. Personal Safety:

a. Wear safety glasses at all times

when working with pumps.
This pump is designed to
handle materials that could
cause illness or disease through
direct exposure. Wear and
use protective clothing when
working on the pump or piping.

b. Do not wear loose clothing that

may become entangled in the
impeller or other moving parts.

c.

Keep clear of suction and
discharge openings. DO NOT
insert fi ngers in the pump with
power connected.

d. Keep work are clean,

uncluttered and properly
lighted: replace all unused tools
and equipment.

e. Keep visitors a safe distance

from the work area. Make
workshop childproof with
padlocks, master switches, and
by removing starter keys.

18. A qualifi ed electrician should

perform all wiring of this pump.
When wiring an electrically driven
pump such as this, follow all
electrical and safety codes, as well
as the most recent National Electric
Code (NEC) and the Occupational
Safety and Health Act (OSHA).

Risk

of

Electric

Shock! Never connect the green (or
green and yellow) wire to a live
terminal!

This

unit

is

not

designed for application involving salt
water or brine. Use with salt water or
brine will void warranty.

Installation

This pump may be installed on a guide-
rail lift-out system for ease of inspection
and service. Guide-rails allow removal
of the pump without disturbing the
piping and eliminates the need to enter
the basin. If installed with a guide-rail
system, place the pump opposite the
infl uent opening to prevent stagnant
areas where solids can settle.

Install the pump on a hard, level surface.
Never place the pump directly on earth,
clay or gravel surfaces. The basin must be
at least 18” in diameter and 30” deep.

The discharge pipe must not be smaller
than the pump discharge.

The motor is provided with a thermal
overload switch (Single Phase Pump
Motors Only). If the motor overloads
or overheats for any reason, the switch
opens, stopping the motor. As soon as
the motor cools to normal temperature,
the switch automatically closes and
restarts the motor. On 3-Phase pumps,

the installer must provide the
Motor Protection. In accordance
with the National Electric Code, all
3-phase pumps must be installed
with magnetic starters having 3
leg overload protection. For duplex
installations, both pump motors must
have separate overload protection.

Hazardous

voltage.

Can shock, burn, start a fi re or kill. When
installing, operating or servicing this
pump, follow electrical safety instructions
below. Only trained service personnel
should install or service this pump.

1. Do not splice the power cord.

2. Do not handle or service this pump

while it is connected to the power
supply.

3. Do not operate the pump unless it

is properly grounded. Connect the
pump according to all applicable
codes.

4. Incorrect voltage can cause a fi re

or seriously damage the motor and
voids the warranty. Make sure that
the frequency and voltage shown
on the nameplate corresponds to
the frequency and voltage of the
electrical supply.

5. Connect the pump to its own

circuit with nothing else on the
circuit. See Chart 1 for pump motor
specifi cations. See Figure 2 for wiring
diagram. Use a Control Panel sized
to match the pump. Refer to Control
Panel installation instructions for
wiring connections information.

6. The pump rotation must be

clockwise as viewed from the top of
the pump. If a three-phase unit runs
backwards, interchange two of the

Model Number

Motor

HP

Voltage

Frequency

Hz

Phase

Motor Full

Load Amps

BAGP1-115

2

115

60

1

15.0

BAGP1-2021

2

230

60

1

14.5

BADSGP1-115

2

115

60

1

20.0

BARDSGP1-2021

2

230

60

1

14.5

BARDSGP1-2001

2

200/208

60

1

16.9

BARDSGP1-2023

2

230

60

3

8.8

BAHGP2-2021

2

230

60

1

24.0

BAHGP2-2021C

2

230

60

1

24.0

BAHGP2-2021E1

2

230

60

1

14.8

BAHGP2-2023

2

230

60

3

12.2

Chart 1 - Motor Specifi cations

www.blueangelpumps.com

7

Operating Instructions

2HP Grinder Pumps

1

17

16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

Figure 6 - BAHGP2 Grinder Series

Service Parts

SERVICE KITS

Upper Volute

(1)

63006-001

Upper Impeller

(2)

63007-001

Motor Assembly

(3, 4, 5, 6, 7, 8, 9,

10, 11, 12 and 13)

63008-001

Lower Mechancial

Seal

(12)

63009-001

Lower Impeller

(14)

63010-001

Lower Volute

(15)

63011-001

Grinder Assembly

(16 and 17)

63012-001

Starting

Components

(not shown)

63013-001

www.blueangelpumps.com

Power Cord 1

Capacitor (Run) 2

Capacitor (Start) 3

Cord Cap 4

Start Mechanism 5

Upper Motor Plate 6

Upper Ball Bearing 7

Dielectric Oil 8

Motor Housing 9

Stator 10

Rotor 11

Lower Ball Bearing 12

Upper Mechanical Seal 13

Moisture Detection Probe 14

Upper Seal Housing 15

Lower Seal Housing 16

Lower Mechanical Seal 17

Volute 18

Pump Impeller 19

Flange with Shredding Ring 20

Grinder Impeller 21

SERVICE KITS

Cord Cap

Assembly

(1 and 4)

63014-001

Capacitors

(2 and 3)

63013-001

Motor Assembly

(5, 6, 7, 8, 9, 10, 11,

12, 13, 14, and 15)

63036-001

Upper Mechanical

Seal (13)

63023-001

Lower Mechanical

Seal (17)

63024-001

Volute

(18)

63026-001

Pump Impeller

(19)

63027-001

Grinder Assembly

(20 and 21)

63029-001

Figure 7 - BADSGP1 Grinder Series

Service Parts

For Replacement Parts or Technical Assistance, Call 1-888-636-6628

Please provide following information:

Address any correspondence to:

- Model number

Blue Angel

- Serial number (if any)

101 Production Drive

- Part description and number as shown in parts list

Harrison, OH 45030 U.S.A.