Lawn sprinkler pump, Installation (continued) – Blue Angel Pumps BWLS200 User Manual

Page 2

Advertising
background image

2

Operating Instructions and Parts Manual

Installation (Continued)

For horizontal runs, lay pipe from the
water source so the upward slope is at
least 1/2” per foot. This eliminates
trapped air. The threaded inlet of the
pump is 2” NPT.

Do not install suc-
tion piping near

swimming areas.

DISCHARGE PIPING

Install a 1-1/2” pipe tee in the pump
discharge to allow easy priming. Plug
the end of the tee opposite the pump
to allow the branch piping to go to the
spray nozzles (See Figure 1). Remove
the pipe plug to fill the pump with
water for priming.

CONNECTION TO WATER SOURCE

The maximum vertical suction lift from
pump to the water level is 25 feet.

DRILLED WELL

1. Install a foot valve on the first sec-

tion of pipe (see Figure 2).

2. Lower the pipe into the well.

3. Add pipe until the foot valve is 10

feet below the lowest anticipated
water level.

Leaking joints or couplings will allow
air to leak into the pipe and cause poor
pump operation. Make sure to use
pipe joint compound or Teflon

®

tape on

all pipe connections.

Locate foot valve

no closer than 2

feet from the bottom of the well so
sand or sediment is not drawn into the
system.

4. After the proper depth is reached,

install a well seal or pitless adapter
to support the pipe.

5. Slope the horizontal pipe upward

toward the pump to eliminate trap-
ping air.

6. When using a foot valve, a priming

tee and plug above the well seal is
recommended.

DRIVEN WELL

1. Drive the point several feet below

the water table.

NOTE: A packer-type foot valve can be
installed in the well (See Figure 3). This
type of foot valve allows the well pipe
to be filled with water when priming
and makes the inlet pipe much easier
to test for leaks. Follow the manufac-
turer’s instructions when installing the
packer-type foot valve.

As an alternative, an in-line check valve
can be used with a driven well (See
Figure 4).

It may be necessary to supply the
pump with multiple well points to
maintain the high flow capability of
this pump. Consult with a plumbing
professional for appropriate materials
and installation instructions.

Leaking joints or couplings will allow
air to leak into the pipe and cause poor
pump operation. Make sure to use
pipe joint compound or Teflon

®

tape on

all pipe connections.

Lawn Sprinkler Pump

To Pump

Well Seal

Well
Casing

Foot Valve

Figure 2

Drive Point

Figure 3

To Pump

Packer Type
Foot Valve

To Pump

Inline Check Valve

Drive Point

Figure 4

Pipe Plug

To Spray
Nozzles

Short
Section
of Pipe

1-1/2” Pipe
Tee

Pump

Figure 1

www.blueangelpumps.com

Advertising