INSTALLATION INSTRUCTIONS

UNPACKING INFORMATION

Verify that you have received all of the following equipment:

- One A-1600 series pump
- 10 ft. 3/8” O.D. Clear vinyl tubing with flow indicator
- One threadless injector (T.I.) Fitting
- One suction tube strainer
- One ceramic weight
- Two pump head tube assemblies (with fittings)
- Two mounting screws

LOCATION AND MOUNTING
CAUTION

ALWAYS WEAR EYE PROTECTION AND PROTECTIVE CLOTHING WHEN
WORKING AROUND CORROSIVE MATERIAL.

A. Choosing a well ventilated area located near the supply tank, Electrical
supply and injection points.
B. The injector may be shelf or wall mounted. Use the inclosed hardware for
wall mounting.
C. When using wall corrosive chemicals, avoid mounting the injector directly
above the supply tank. Although the pump housing is designed to withstand
corrosion, some chemical fumes may damage the unit.
D. Your solution tank should be sturdy plastic and chemically resistant to the
chemicals you are using to protect from fume, a tight fitting cover should be in
place at all times. A variety of tanks are available from the factory.

ELECTRICAL CONNECTIONS

WARNING - RISK OF ELECTRIC SHOCK

Be certain you connect the unit to the proper supply voltage. Using the incorrect
voltage will damage the injector and may result in injury. The units voltage
requirements is printed on the name plate

A-1600 MODELS

A-1600 Model Injector are supplied with a junction box and cover. To reduce
the risk of electric shock when field wiring, be certain that the grounding
conductor is attached to the green ground screw, located inside the junction box.

A-1600T MODELS

(Timer Equipped Model)

115V Model Injector are supplied with a ground wire conductor and a grounding
type attachment plug. To reduce the risk of electric shock, be certain that it is
connected only to the properly grounded, grounding type receptacle. A ground
fault interrupter (GFI) receptacle is recommended for use in wet locations.

24V/230V Models Injectors are supplied with a ground wire conductor. To
reduce the risk of electric shock, be certain that the green grounding conductor
is connected only to a properly grounded field wiring box.