Operating instructions, Page 7, Blue-white – Blue-White A-1600 FLEXFLO Peristaltic Pump User Manual

Page 7: Adjusting the output, Measuring the output figure 5

Advertising
background image

Page 7

Suction

Tubing

Discharge

Tubing

Graduated

Container

(not provided)

Blue-White

Injection Fitting

Pump

Blue-White

R

This volumetric test will take into
account installation factors such as
line pressure, fluid viscocity, specific
gravity, etc. This test is the most
accurate for measuring the injector’s
output in an individual installation.

1. With the injector installed under
normal operating conditions, place
the foot valve/strainer in a large
graduated container.

2. Fill the container with the
chemical to be injected and run the
unit until all air is removed from the
suction line.

3. Refill the container, if necessary,
and with the foot valve in the
solution, note the amount of
chemical in the container.

4. Run the injector for a measured
amount of time and note the amount
of chemical injected.

ADJUSTING THE OUTPUT

A. The pause control knob adjusts the cycle timer’s time on. The model A-1600T
standard cycle timer set at one minute. (+-10%) Other cycle lengths are available.
B. To adjust the amount of time on, turn the pause control knob to the correct
setting. ½ equals approximately 30 seconds on. 3/4 equals approximately 45
seconds on, etc.

MEASURING THE OUTPUT

FIGURE 5

L

R

OPERATING INSTRUCTIONS