F-2000, 0 temperature vs. pressure, 0 calibration constants – Blue-White F-2000 – Pipe Fittings User Manual

Page 2: I.p.s. pipe (meets astm-d-1785), Page 2, Molded inline bodies (male npt connection), Saddle mount models (pipe insertion connection)

Advertising
background image

F-2000

Page 2

1.0

Temperature vs. Pressure

PSIg (BAR)

Temperature

When mounted on

Molded PVC Tee or PVC pipe units

180°F (82.2°C)

190°F (87.8°C)

200°F (93.3°C)

170°F (76.7°C)

160°F (71.1°C)

150°F (65.6°C)

When mounted on

Polypropylene and PVDF inline units

100°F (37.8°C)

90°F (32.2°C)

80°F (26.7°C)

70°F (21.1°C)

0 (0)

60 (4.1)

120 (8.3)

180 (12.4)

240 (16.5)

300 (20.7)

Fig. 1

Note: Pressure and temperature limits are inversely proportional.

140°F (60°C)

130°F (54.4°C)

120°F (48.9°C)

110°F (43.3°C)

I.P.S. PIPE (Meets ASTM-D-1785)

2.0

Calibration Constants

Pipe Size

(MM)

PN

Rating

Pipe I.D. (MM)

Flow Range

(LPM)

K-Factor

(Pulse/L)

Rate Scale

Factor (Sr)

Rate Display

Decimal Point

Total Scale

Factor (St)

Total Display

16

10

10
16

50
50
63
63

45.2
42.6
57.0
53.6

70.0 - 700.0
70.0 - 700.0

110 - 1100
110 - 1100

16.561
20.719
10.522

11.830

36.2297
28.9588
05.7023
05.0720

0000.0
0000.0

00000
00000

00.0604
00.0483
00.0950
00.0845

00000
00000
00000
00000

16

10

10
16

90
90

110
110

81.4
76.6
99.4
93.6

230 - 2300
230 - 2300
350 - 3500
350 - 3500

5.294
5.944
2.942
3.107

11.3335

10.0944
20.3969
19.3133

00000
00000
00000
00000

00.1889
00.1682
00.3399
00.3219

00000
00000
00000
00000

16

10

10

160
160
200

144.6
136.2
180.8

720 - 7200
720 - 7200

1150 - 11500

1.386
1.574
0.927

43.2782
38.1081
64.7077

00000
00000
00000

00.7213
00.6351
01.0785

00000
00000
00000

RATE 1

RATE 2

TOTAL 1

TOTAL 2

Standard Flow Range - LPM (liters per minute)

Molded Inline Bodies (Male NPT connection)

METRIC PIPE PN10 & PN16 (Meets DIN 8062)

Note:

The values in the following tables are based on laboratory testing of nominal pipe dimensions. The F-2000 sensor is factory calibrated to ±1%
of full scale linearity. Your actual accuracy will vary based on your pipe I.D. And other installation factors.

Saddle Mount Models (Pipe Insertion connection)

Pipe Size

(in.)

Pipe Sch.

Inline

Inline

Inline
Inline

3/8

1.0

Body I.D. (In.)

0.375
0.500
0.660
0.840

Flow Range

(GAL/Min)

.800 - 8.000
2.00 - 20.00
3.00 - 30.00
5.00 - 50.00

K-Factor

(Pulse/GAL)

1456.31
1034.48

612.25
338.60

Rate Scale

Factor (Sr)

41.2000
05.8000
09.8000
17.7200

Rate Display

Decimal Point

00.000
000.00
000.00
000.00

Total Scale

Factor (St)

00.0069
00.0097
00.0163
00.0295

Total Display

Decimal Point

0000.0
0000.0
0000.0
0000.0

RATE 1

RATE 2

TOTAL 1

TOTAL 2

1 /2

3/4

16

200

170.2

1150 - 11500

1.008

59.5501

00000

00.9925

00000

10

250

226.2

1700 - 17000

0.565

106.232

00000

01.7705

00000

10

315

285.0

2700 - 27000

0.353

170.003

00000

02.8334

00000

RATE 1

Pipe Size

(in.)

Pipe Sch.

Inline

Inline

Inline
Inline

3/8
1/2
3/4
1.0

Body I.D. (In.)

0.218
0.250
0.375
0.500

Flow Range

(GAL/Min)

.400 - 4.000
.500 - 5.000
.800 - 8.000
2.00 - 20.00

K-Factor

(Pulse/GAL)

2926.83
2419.35
1518.99
1034.48

Rate Scale

Factor (Sr)

20.5000
24.8000
39.5000
05.8000

Rate Display

Decimal Point

00.000
00.000
00.000
000.00

Total Scale

Factor (St)

00.0034
00.0041
00.0066
00.0097

Total Display

Decimal Point

0000.0
0000.0
0000.0
0000.0

RATE 2

TOTAL 1

TOTAL 2

3/8” - 1” pipe sizes - Standard Range #1 - GPM (gallons per minute)

3/8” - 1” pipe sizes - Low Range #2 - GPM (gallons per minute)