! The F-2000 can be mounted on horizontal or vertical runs of pipe (see figure 3 and 4). Mounting at the vertical

(twelve o'clock) position on horizontal pipe is recommended (see figure 7). Mounting anywhere around the
diameter of vertical pipe is acceptable, however, the pipe must be completely full of water at all times. Back
pressure is essential on downward flows.

! The F-2000 can accurately measure flow from either direction provided the minimum inlet and outlet conditions

are met.

The F-2000 is designed to withstand outdoor conditions. A cool, dry location, where the unit can be easily ser-
viced is recommended.

4.0

HOW TO INSTALL THE F-2000

The F-2000 was designed to be installed and operated by qualified personnel only. Do not attempt to install or operate the
F-2000 if you are unsure. Seek qualified assistance. Please note that warranty coverage does not include damage due to
misuse or improper installation.

4.1

Mounting Location

*See Minimum Pipe Lengths table on previous page.

Vertical Mount

Fig. 4

MINIMUM

INPUT

LENGTH

MINIMUM

OUTPUT

LENGTH

I.D.

FLOW

Horizontal Mount

Fig. 3

MINIMUM

INPUT

LENGTH

MINIMUM

OUTPUT
LENGTH

I.D.

FLOW

Angle Mount on Horizontal Pipe

45 Acceptable

°

45 Acceptable

°

Recommended

Vertical

Fig. 5