Mpm, apm, ppm, & lti series modbus, Register tables serial communication – Dwyer PPM User Manual

Page 28

Advertising
background image

MPM, APM, PPM, & LTI Series Modbus

®

Register Tables

Serial Communication

Page 28

Register

1

Name Access

Limits or

Range

2

Units

Data

Type

3

Function

Code(s)

Comments

Number Address

(hex)

43117 – 43118

3116 – 3117

(C2C – C2D)

Scale Pulse

Input 27

Read Write

0.0 to 99999.9

Hz

Floating point

03, 04,

06, 16

43119 – 43120

3118 – 3119
(C2E – C2F)

Scale Pulse

Input 28

Read Write

0.0 to 99999.9

Hz

Floating point

03, 04,

06, 16

43121 – 43122

3120 – 3121

(C30 – C31)

Scale Pulse

Input 29

Read Write

0.0 to 99999.9

Hz

Floating point

03, 04,

06, 16

43123 – 43124

3122 – 3123

(C32 – C33)

Scale Pulse

Input 30

Read Write

0.0 to 99999.9

Hz

Floating point

03, 04,

06, 16

43125 – 43126

3124 – 3125

(C34 – C35)

Scale Pulse

Input 31

Read Write

0.0 to 99999.9

Hz

Floating point

03, 04,

06, 16

43127 – 43128

3126 – 3127

(C36 – C37)

Scale Pulse

Input 32

Read Write

0.0 to 99999.9

Hz

Floating point

03, 04,

06, 16

43129

3128

(C38)

Remote Scale

Pulse Flag

Write Only

0xFF00 to

execute remote

scaling.

None

Unsigned

integer

06, 16

Used to remote scale the Pulse input. Caution! See Note 5.

44001 – 44002

4000 – 4001

(FA0 – FA1)

Scale PV2 mA

Display 1

Read Write -99999 to 999999

User defined

Floating point

03, 04,

06, 16

After all the Display and Input values have been sent, write
0xFF00 to register 44129.

44003 – 44004

4002 – 4003

(FA2 – FA3)

Scale PV2 mA

Display 2

Read Write -99999 to 999999

User defined

Floating point

03, 04,

06, 16

44005 – 44006

4004 – 4005

(FA4 – FA5)

Scale PV2 mA

Display 3

Read Write -99999 to 999999

User defined

Floating point

03, 04,

06, 16

44007 – 44008

4006 – 4007

(FA6 – FA7)

Scale PV2 mA

Display 4

Read Write -99999 to 999999

User defined

Floating point

03, 04,

06, 16

44009 – 44010

4008 – 4009

(FA8 – FA9)

Scale PV2 mA

Display 5

Read Write -99999 to 999999

User defined

Floating point

03, 04,

06, 16

44011 – 44012

4010 – 4011

(FAA – FAB)

Scale PV2 mA

Display 6

Read Write -99999 to 999999

User defined

Floating point

03, 04,

06, 16

44013 – 44014

4012 – 4013

(FAC – FAD)

Scale PV2 mA

Display 7

Read Write -99999 to 999999

User defined

Floating point

03, 04,

06, 16

44015 – 44016

4014 – 4015
(FAE – FAF)

Scale PV2 mA

Display 8

Read Write -99999 to 999999

User defined

Floating point

03, 04,

06, 16

44017 – 44018

4016 – 4017

(FB0 – FB1)

Scale PV2 mA

Input 1

Read Write -99.999 to 99.999

mA

Floating point

03, 04,

06, 16

44019 – 44020

4018 – 4019

(FB2 – FB3)

Scale PV2 mA

Input 2

Read Write -99.999 to 99.999

mA

Floating point

03, 04,

06, 16

44021 – 44022

4020 – 4021

(FB4 – FB5)

Scale PV2 mA

Input 3

Read Write -99.999 to 99.999

mA

Floating point

03, 04,

06, 16