Outputs oscar/marlin – Allied International Home Security System User Manual

Page 55

Advertising
background image

Camera interfaces

Hardware Installation Guide V2.0.0

55

Outputs OSCAR/MARLIN

The OSCAR and MARLIN cameras have 2 non-inverting outputs with open
emitters. These are shown in the following diagram:

Figure 31: Output schematics with external resistor R (OSCAR/MARLIN)

Parameter

Test condition

Value

Emitter current

Max. 500 mA

Emitter collector voltage

Max. 45 V

Figure 32: Output parameters (OSCAR/MARLIN)

OutVCC

Resistor value

5 V

1 k

Ω

12 V

2.4 k

Ω

Figure 33: OutVCC (OSCAR/MARLIN)

Note

L

OSCAR/MARLIN

Voltage above +45 V may damage the optical coupler.

The output connection is different to the AVT Dolphin
series to achieve higher output swing.

Depending on the voltage applied at OutVCC and the
type of input which you want to drive, it may be neces-
sary to switch an external resistor in series between
GPOut1 and ground. The use of 1 k

Ω @ 5 V or 2.4 kΩ @

12 V can be recommended. Typical delay is not more
than 40 µs.

Note

L

For information on output features (IntEna, Fval, Busy) and
configuration via registers see Technical Manuals.

Advertising