MEASURING PRESSURE

The analyzer can be used to measure pressure by connecting tubing to the appropriate ports.


Standard Pressure Report ....

this mode is accessed via the MENU function.

This mode allows a tightness test to be carried out automatically.

The times for the test can be set by the user.

From the start of the test the analyzer waits 60 secs to allow temperature stabilization, then
records and displays the pressure reading at the start of a 120 second countdown. The live
pressure reading is displayed during the 120 second countdown and then locked at the end of
the countdown. The display then shows start pressure and finish pressure. The summary
results can then be printed as below:


Pressure Test Printout

DWYER 1207A

1.0

Serial No.

123456789



..............................................

Tightness Test
..............................................

LOG

03

TIME 14:58 11/01/09


PRS_1

INWG 20.110

PRS_2

INWG 19.998

Duration

mins 2:00


................................................
customer

................................................
appliance

.................................................
Ref:

..................................................