FUTEK IPM52x (D520) Digital Display User Manual

Page 33

Advertising
background image

32

Impedance 50 Ohms

10 Mohm 10 Mohm 10 Mohm

10 Mohm 10 Mohm

Resolution 1 uA

1 uV

10 uV

10 uV

100 uV

1 mV

Over-range
Capability,
minimum


10%


10%


10%


10%


10%


10%

Normal Mode Rejection
Ratio


63 bB, 50/60 Hz

Common Mode
Rejection Ratio


130 dB, 50/60 Hz

Response Time

100 msec max to display (10 updates / sec)

Internal Resolution

22 bits

Conversion Time

52mS

Digital filter

60 Hz in 4 1/2 digit mode/50Hz in 5 1/2 digit mode

Warm Up Time

15 minutes

Operating Temp range -20°C to 60°C

Storage Temp range

-20°C to 85°C

Humidity

To 95%, non-condensing

AC supply voltage

115 or 220 VAC

Power Consumption

7 Watts maximum

Isolation

Signal Input to Earth Ground: Safety rated to 450 Vrms, 2200Vp high voltage test

Option board to Earth Ground: Safety rated to 450 Vrms, 2200Vp high voltage test

Option board to Signal Input: 400 Vp

Power to Earth Ground:

Safety rated to 500 Vrms, 4000 Vp high voltage test

Main Bd. Relay

Contact Rating : 30VDC @ 1 A

Advertising