Voltage configuration – FUTEK IPM650 Series User Manual

Page 81

Advertising
background image


EM1004-B

- 81 -

10 Thomas, Irvine, CA 92618 USA

Tel: (949) 465-0900

Fax: (949) 465-0905

Toll Free: (800) 23 FUTEK

6.4.4

Voltage Configuration

Scroll to “

VOLTAGE CONFIG

” from “

OUTPUT CONFIG

” using the

▲▼

keys and press ENTER.

Use the

◄►

keys to select uni-polar which is 0 to 5 volts (negative full scale is mapped to 0 VDC, zero

load is mapped to 2.5 VDC and plus full scale is mapped to +5V) or bipolar which is -5 VDC to 5 VDC
(negative full scale is mapped to -5 VDC, zero load is mapped to 0 VDC and plus full scale is mapped to
+5VDC).

A prompt will be shown to set this value as a default setting.


SELECT DESIRED

VOLTAGE CONFIG

USING

◄,► KEYS

[BI-POLAR]

ALARM RELAY1

ALARM RELAY2

► VOLTAGE CONFIG

CURRENT VALUE





WOULD YOU LIKE

TO SAVE AS

DEFAULT?

<YES> <NO>