Dimensions, A b c d, Redimon – Hoyles Redimon v3 Monitor User Manual

Page 2: Hoyles electronic developments ltd, Panic strip

Advertising
background image

In M ode 2 operation a 10K End of Line resistor is fitted at the remote
end of each length of

. Pressing either

twice, within a 5 second window will be seen as an alarm condition.
This double action reduces the number of false alarms caused by
accidental pressing. If the

becomes disconnected in any

way, or is held pressed for longer than 5 seconds, a fault condition is
generated. The Redimon requires 12 volts dc and provides volt free
changeover contacts for both alarm and fault. A reset button is
provided.

eg. Footswitch or

pushbutton.

Panic Strip

Panic Strip

Panic Strip

Redimon can also be used to create a double pole EOL circuit

for any

momentary action normally open device.

Redimon is supplied with two 6k8 end of line resistors fitted to the
terminals AB and CD for Mode 1 operation and test purposes.
These resistors should be replaced with ones of 10K value for
Mode 2 operation. If only one length of

is being

monitored one of these resistors should be left in either AB or CD
terminals and the other terminals used for the

.

Panic Strip

Panic Strip

Any other type of non-latching open circuit button or switch could
be wired across

Panic Strip

circuits to complement the system

as in

Panic Strip

2 shown below.

Under normal circumstances the GREEN LED will be illuminated to show that power is on and the circuits are healthy. When
either Panic Strip is operated the RED LED will illuminate and the alarm relay will change over. If either of the Panic Strip
circuits becomes disconnected the RED and GREEN LEDs will alternate and the fault relay will operate, this will restore when
the circuit has been repaired. To reset the Panic Strip from an alarm condition press the Reset button.

Dimensions in mm

Dimensions

R

12 Volts dc power
45ma max

Alarm output
Fault output

Panic Strip Type 3

Panic Strip Type 3

Use these changeover contacts to connect to the personal attack circuit of your intruder alarm.

Use these changeover contacts to connect to the tamper circuit of your alarm

11 - 14 volts dc at all times. Quiescent current 30ma Max current 45ma

E.O.L 10K

E.O.L 10K

ALARM

OUTPUT

FAULT

OUTPUT

TAMPER
OUTPUT

T1

T2

10K Terminating resistors

Panic Strip

Type 2

Panic Strip

Type 3

Panic Strip

Type 3

Panic Strip

Type 2

These contacts are rated @ 30vdc 1A

Optional open circuit
non-latching push button

A B C D

NOTE

Panic Strip

SHOULD NEVER BE

CONNECTED DIRECTLY TO MAINS
VOLTAGE CIRCUITS.
IT IS ONLY RATED FOR SAFE WORKING
ON 43 VOLTS MAXIMUM.

T1 and T2 are normally closed. Opening this circuit will cause a fault
until the circuit is closed again. If wired as shown, removing the unit
cover will cause a fault to be indicated, until the cover is replaced.

T. 01744 886600 F. 01744 886607 E. [email protected] W. www.hoyles.com

Hoyles Electronic Developments Ltd

Dwg No: 60136 Oct 2011

Mode 2 operation - Double push

Latching monitor unit for Panic Strip

v3

Redimon

87.0

18.0

18.0

8

7

.0

v3

Redimon Monitor

Press to Reset

v3

Redimon Monitor

Press to Reset

NO

NO

COM

RELAY 1

RELAY 2

COM

NC

NC

TAMPER

SWITCH