Aduc812 – Analog Devices ADuC812 User Manual

Page 47

Advertising
background image

REV. B

ADuC812

–47–

12 MHz

Variable Clock

Parameter

Min

Max

Min

Max

Unit

Figure

EXTERNAL PROGRAM MEMORY

t

LHLL

ALE Pulsewidth

127

2t

CK

– 40

ns

52

t

AVLL

Address Valid to ALE Low

43

t

CK

– 40

ns

52

t

LLAX

Address Hold after ALE Low

53

t

CK

– 30

ns

52

t

LLIV

ALE Low to Valid Instruction In

234

4t

CK

– 100

ns

52

t

LLPL

ALE Low to

PSEN Low

53

t

CK

– 30

ns

52

t

PLPH

PSEN Pulsewidth

205

3t

CK

– 45

ns

52

t

PLIV

PSEN Low to Valid Instruction In

145

3t

CK

– 105

ns

52

t

PXIX

Input Instruction Hold after

PSEN

0

0

ns

52

t

PXIZ

Input Instruction Float after

PSEN

59

t

CK

– 25

ns

52

t

AVIV

Address to Valid Instruction In

312

5t

CK

– 105

ns

52

t

PLAZ

PSEN Low to Address Float

25

25

ns

52

t

PHAX

Address Hold after

PSEN High

0

0

ns

52

MCLK

ALE (O)

PSEN (O)

PORT 0 (I/O)

PORT 2 (O)

t

LHLL

t

AVLL

t

LLPL

t

PLPH

t

LLIV

t

PLIV

t

PLAZ

t

LLAX

t

PXIX

t

PXIZ

t

PHAX

t

AVIV

PCL (OUT)

INSTRUCTION

(IN)

PCH

Figure 51. External Program Memory Read Cycle