DEVICE

SAFE S.6

Emergency stop

APPLICATIONS

and safety gate monitoring relay

APPROVALS

CE, TÜV, UL, C-UL

CONTACTS

2 normally open safety

LED indicators for status and supply diagnostic

SPECIAL CHARACTERISTICS

Selectable opposite polarity between channels

LED

Power, channel 1 and channel 2

24 V AC / DC (without galvanic disconnection, but with a fuse F1)

OPERATING VOLTAGE

24 V DC (without galvanic disconnection, but with an electronic fuse)

24, 48, 110-127, 230 V AC (with galvanic disconnection/transformer)

POWER CONSUMPTION

ca. 3 VA

START UP DELAY / FALLBACK TIME

< 150 ms / < 30 ms

CONTACT CAPACITY max.

6 A, 250 V AC, 24 V DC

CONTACT CAPACITY min. at 24V DC (*)

100 mA

(*)

SIMULTANEITY

Simultaneous protective door contacts : ca. 65 ms

ENVIRONMENTAL TEMPERATURE

-25°C to + 55°C

SWITCHING CAPACITY

1380 VA (resistive load)

CONTACT SECURITY

6 A quick acting or 4 A time lag

OPERATING MODE

(*) We offer all devices who have a CONTACT

CAPACITY of min. 100 mA at 24 V DC with

hard gold-plated contacts. In this way the

CONTACT CAPACITY of min. 100 mA is only 4 mA.

Please ask our sales team!

CONNECTION DIAGRAM

A supply voltage must be applied at terminals A1 and A2 in order to operate

the device. If this is done there is a voltage of 24V DC at terminal T11.

Terminals T12 and T22 must be wired as shown in the application

examples. To start the unit terminal T11 must be bridged with terminal T34

by means of a closing contact or terminal T34 must receive a 24V DC

impulse (short time bridging of the connection terminals T11-T34). If this is

down contacts 13-14 and 23-24 close. The LEDs channel 1 and channel 2

illuminate. In series with the start button and terminals T11 / T34 the

function of an external contactor can be monitored.

(*) We offer all devices which have a contact capacity of min. 100mA at 24V

DC with hard gold-plated contacts. In this way you get a contact capacity of

4mA.

T34 T33 T11

T12

T22 T44 /

PE

Not-Halt

E-Stop

Start

FUNCTION CIRCUIT DIAGRAM

~~

-

+

=

~

~

T34

A2 (-)

A1 (+)

T11

T33

T12

T22

13 23

K3

K2

K1

F1

T1

K1

K3

K2

24

14

T44/PE

Certifications according to

Safety relevant substance data

Depending on wiring (only max. values are given)

EN ISO 13849-1: PLd/e, Cat.3 /4

MTTFd: 74,15 years / high, DC: Cat. 3: 90% / medium, Cat. 4: 99% / high

CCF: achieved