1.1.

Technical features

Features

OWS-T

Type

Series heating cable set, twin conductor.

Voltage

240/208V, 347V

Mat width

24” (610 mm) and 36” (914 mm)

Linear density

12W/ft. (39W/m)

Density (3” [76 mm] spacing)

50W/sq. ft. (538W/sq. m) at 240V and 347V,
37.5W/sq. ft. (404W/sq. m) at 208V

Covered surface

6.5 sq. ft. (0.84 sq. m) to 126.7 sq. ft. (11.14 sq. m)

Cold lead length

16' 4'' (5 m)

Cold lead outer diameter

3/8” (9.5 mm)

Cold lead gauge

12 AWG or 14 AWG (according to maximum allowable load)

Minimum bend radius

1” (25 mm)

Heating cable diameter

1/4” (7 mm)

Resistance wire insulation

Fluoropolymer (ECTFE) 0.014” (0.35 mm) thick

Outer sheath insulation

Polyolefin (EPR) 0.08'' (2 mm) thick

Cold lead outer sheath insulation

PVC 0.03”(0.76 mm) thick

Ground

Braided copper shielding 17 AWG

Maximum long-term exposure
temperature

105 °C (221 °F)

Maximum exposure temperature
for 10 minutes

220 °C (428 °F)

Minimum installation temperature

-15 °C (5 °F)

Certification

Marking

Canada: WS, X

1

United States: Type C

Warranty (see Section 7)

10 years on heating cable

1

For outdoor embedded applications.

Resistance wires

Resistance wire insulation (fluoropolymer)

Braided copper shielding (ground)

Outer sheath insulation (polyolefin)

Ø

1/4''

7 mm

Figure 1: Cable cross-section