㧝PARTS NAME

Head cover

Spare bulb

Reflector

Bulb

Motor

Name plate

Power supply wire

Lens

Signal line

Body

Volume

̪Lot number indicated

2. REPLACEMENT PARTS

3.

MODEL NO

CONFIGURATION

̪

If you have question please feel to contact us about other parts.

࡮ The replacement parts are prepared. Please ask your local

distributor for availability.

㧷㧶㨀-㧟㧝㧜㧷㧭-㧾㨅㧳

Model of sound
K: alarm 8 sounds
L: chime 2 sounds +
melody 6 sounds

Number of
stacked lamps
1: 1 stacked lamp
2: 2 stacked lamps
3: 3 stacked lamps

Rated voltage
02: 24V AC/DC
10: 100V AC
12: 120V AC
20: 220V AC
24: 240V AC

Type of sound
Refer to "8. SPECIFICATIONS

Lens color
R; Red
Y: Amber
G: Green
B: Blue

1. Type KJT

㧷㧶㧼㨂-㧟㧝㧜㧿-㧾㨅㧳

Memory capacity

(The number of total recording second)

S: 1Mbit 16 seconds
٧T: 2Mbit 32 seconds
٧F: 4Mbit 64 seconds

Number of
stacked lamps
1: 1

stacked lamp

2: 2

stacked lamps

3: 3

stacked lamps

Rated voltage
02: 24V DC
10: 100V AC
12: 120V AC
20: 220V AC
24: 240V AC

Lens color
R; Red
Y: Amber
G: Green
B: Blue

2. Type KJPV

̪The model indicated "٧" is custom order item.

 HOW TO MOUNTING

Make mounting holes in wall.( Refer to the following installation drawing )
Tighten with nuts and bolts.


When it is processed from the mounting surface side.

٨
٨

٨

٨

Do not install with wrong direction, as it may be water leaked.
Signal Tower must be installed in a vertical position where it has
enough strength and less vibration. Do not install it horizontally or
reversely.
When the installation of this product requires the construction,
please ask to specialist. Electric shock, fire and fall may occur.

When installing the unit in a high place, choose the place where
a foothold can be secured for case in repairs.

Caution

 HOW TO WIRING CONNECTION

٨
٨
٨

٨
٨

٨

٨
٨

٨

٨

٨

٨

٨

٨

٨

Turn off the power supply before making wiring connections.
Neglecting to so may cause an electric shock.
When you have questions for the method of special operation or
plural units operation, we recommend you to ask our sales office
before wiring.
Do not pull lead wire and push it in body when wiring.
Wiring should be careful enough there to be for no mistake. If wiring
is mistaken,an internal circuit will be damaged and it will become
the cause of a fire.
During connection, refer to the wiring example. Be sure to use crimp
type terminal connectors.
Make sure to set fuse in a power supply side, please connect a fuse.
When wiring is completed, make sure ends of any unused wires
are insulated (Taped).
KJT series: alarm or chime sounds only when the signal lines are
connected, there is no one shot input.
After the connection (of the sound line to COM), it could take about
1 second to start the sound. Consider this delay time so that it will
not cause any problems on the system.
KJPV series a signal greater than 100ms is necessary to start/stop
playback.
KJPV series: When input of less than 100ms is received on the
signal line, a noise output may turn on momentarily even though
no message playback is taking place.
Due to the individual difference in frequency of melody IC, there
may be a difference in tone or pitch of melody or alarm.
In case of using two or more products, deviation in playback sound
of alarm or melody may occur even if operated simultaneously.
Sound pressure level in specifications is the maximum level.
Operating sound pressure level may be lower than the specified
level due to the type of melody or surge voltage.

Caution

mounting hole

4-

Ǿ7

Name plate

74

74

12

12

4

wire exit

Ǿ11

㧔power line㧕

wire exit

Ǿ11

㧔signal line㧕

1. Wiring example

̆
̆

Red

̆

Red

Orange

Red

Orange
Green

TYPE

1 light

3 light

2 light

Wire color

Common wire
signal line (1ch)

Brown wire

Black wire

White wire

Sky blue wire

signal line (2ch)

Yellow wire

signal line (3ch)

Pink wire

signal line (4ch)

Light green wire

signal line (5ch)

Purple wire

signal line (6ch)

Gray wire

signal line (7ch)

White wire

signal line (8ch)

Blue wire

Rotating light (1-light)

Green wire

Rotating light (2-light)

Orange wire

Rotating light (3-light)

Red wire

Power supply wire

Outer contact

1

2

3

Fuse 5A or up

Ԙ

ԙ

Ԛ

Type KJT

1.

Type KJT

Power
supply

( + )

( - )

Wire color (Rotating light)

̆
̆

Red

̆

Red

Orange

Red

Orange

Green

TYPE

1 light

3 light

2 light

Wire color

Common wire
signal line (1ch)

Brown wire

Black wire

White wire

Sky blue wire

signal line (2ch)

Yellow wire

signal line (3ch)

Pink wire

signal line (4ch)

Light green wire

STOP

Blue wire

Rotating light (1-light)

Green wire

Rotating light (2-light)

Orange wire

Rotating light (3-light)

Red wire

Power supply wire

Outer contact

1

2

3

Fuse 5A or up

Ԙ

ԙ

Ԛ

Type KJPV

Power
supply

( + )

( - )

Wire color (Rotating light)

2. Power supply wiring

٨

٨

Confirm specified voltage as indicated on "3. TYPE No. CONFIGURATION",
and connect accordingly.
When 24V DC is used, make a black line a (-).

3. Signal line wiring

٨

٨

٨

In case of using relay contact, connect diode for preventing backward
voltage to primary side of the diode.
Wire signal line as short as possible for preventing noise. Use twisted
pair shielding wire for extension and junction.
Wiring signal line around high voltage wire or at a place influenced by
induced noise may cause wrong works and damages of internal circuit.

4. How to use

٨

٨

A different type of alarm, chime or melody. Can be selected by
connecting each line 1 (Sky blue)

㨪8 (blue) with COM (black).

A rotating light rotates when a COM(Brown) is connected with the
signal line(Red, Orange, Green) for the rotating lights.
If there are more than 2 signals, higher number will be prioritized.

8ch

㧪 7ch 㧪࡮࡮࡮࡮࡮ 2ch 㧪 1ch

(Blue) (White)

(Yellow)(Sky Blue)

2. Type KJPV....1Bit signal input

3. KJPV....4 Bit binary input ( Custom order item )

٨

٨
٨
٨
٨

٨

٨

٨
٨

٨

٨
٨
٨

The message of the channel witch had the input in each terminal of 1
(Sky blue) to 4(Light green) is reproduced ones busy output may turn on
to the signal input 100ms or less instantaneously, without reproducing a
message.
While playing back a channel in which nothing is recorded, you can hear only noise
While reproducing a message the input of those other than STOP terminal is not received.
A STOP INPUT needs the input for 100ms or more.
The greater number has priority when any of the channels are activated
simultaneously.

Only rotating light works while short-circuiting signal wire for rotating light
(Red) and common wire (Brown).

STOP

㧪 4ch 㧪 3ch 㧪 2ch 㧪 1ch

㧔Blue㧕㧔Light green㧕㧔Pink㧕 㧔Yellow㧕㧔Sky blue㧕

3CH

3CH

2CH

2CH

4CH

1CH

4

3

Message type

Input

terminal

2

1

100ms or up

100ms or up

STOP

Input binary signal to 1(Sky blue)

㨪4(Light green) can play back each message

from on 1 to 15, rotating light at the same time during the regeneration too.
The first binary signal should be less than 10ms. The second signal more than 100ms.
If this is not performed in this sequence, there may malfunction such as a
different channel well be played back or an incorrect action of BUSY signal.
When the channel currently not recorded is reproduced, noise sound is
outputted while a signal is being inputted.
While reproducing a message the input of those other than stop terminal is not received.
A STOP INPUT needs the input for 100ms or more.
Only rotating light works while short-circuiting signal wire for rotating light (Red)
and common wire (Brown).

Signal input time chart

Signal input time chart

10ms within

15CH

4

STOP

3

Message type

Input

terminal

2

1

100ms or up

100ms or up

Message

NO.

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

1

ޓޓ0ޓޓ0ޓޓ0

0

ޓޓ1ޓޓ0ޓޓ0

1

ޓޓ1ޓޓ0ޓޓ0

0

ޓޓ0ޓޓ1ޓޓ0

1

ޓޓ0ޓޓ1ޓޓ0

0

ޓޓ1ޓޓ1ޓޓ0

1

ޓޓ1ޓޓ1ޓޓ0

0

ޓޓ0ޓޓ0ޓޓ1

1

ޓޓ0ޓޓ0ޓޓ1

0

ޓޓ1ޓޓ0ޓޓ1

1

ޓޓ1ޓޓ0ޓޓ1

0

ޓޓ0ޓޓ1ޓޓ1

1

ޓޓ0ޓޓ1ޓޓ1

0

ޓޓ1ޓޓ1ޓޓ1

1

ޓޓ1ޓޓ1ޓޓ1

1

ޓޓ2ޓޓ3ޓޓ4

Terminal Number

Message

NO.

1

ޓޓ2ޓޓ3ޓޓ4

Terminal Number

Binary input code

External
equipment

KJT / KJPV

KJT / KJPV

1

㧔Sky blue㧕

COM

㧔Blown㧕

1

㧔Sky blue㧕

COM

㧔Blown㧕

5mA

φ

Contact output

External
equipment

5mA

φ

NPN open collector output

Outer contact capacity

50mA or up

45V or up

1mA or less

1V or less

Current

capacity

Withstand

voltage

leak

current

ON

voltage

24V

24V

࡮Head cover
࡮Lens (per color)
࡮Motor (per voltage)
࡮Bulb (per voltage)

-2-

-3-

-4-

-5-

Advertising