Maintenance

34. Reinstall lift brackets with top surface lip on

inside.

35. Reinsert circuit breaker through hole in cover,

reattach cover, circuit breaker boot, and wiring
grommet.

36. Verifying lifter cams are on correct side, reattach

handle assembly and belt covers.

37. Reattach dome cover.

38. Reattach solution tank and reconnect top hose.

(Deluxe Only)

39. If new belts were installed, run the machine

unloaded for 10 minutes to seat them properly.

Motor Replacement & Toothed Belt
Tensioning

1. Disconnect machine power supply.

2. Detach quick disconnect hose from top of

solution tank. (Deluxe Only)

3. Remove elastic straps and solution tank. (Deluxe

Only)

4. Remove two dome screws and dome assembly.

5. Remove the circuit breaker boot and push the

circuit breaker clear of cover.

6. Mark left and right on the lift cams.

7. Remove the two cam bolts. This will also free the

lift cams.

NOTE: There are four plastic bushings that the
handle pivots on, leave them on the motor clamps.

8. Remove the handle assembly.

9. Unscrew the wiring grommet from the main

cover, and set retaining bracket and screw aside.

10. Remove the front and back screws and move the

main cover to the side.

NOTE: The handle assembly and cover are still
attached to the frame by wiring. Be careful not to
pinch wiring when reassembling.

11. Remove the (2) plastic finger guards.

12. Remove the motor clamps and lift brackets.

DOME

COVER

CIRCUIT BREAKER
& BOOT

WIRING GROMMET

LIFTING CAM

LIFTING CAM

LEFT

RIGHT

LIFT BRACKET

MOTOR CLAMP

MOTOR

PLASTIC FINGER
GUARD (2)

86269870 CARPET MAINTAINER