Specifications, Inverter features, Mounting your inverter – ProMariner TruePower 200-400 User Manual

Page 6

Advertising
background image

4

F e a t u r e s / I n s t a l l a t i o n G u i d e l i n e s

15

S p e c i f i c a t i o n s

Specifications

TruePower

200W

400W

Power (W)

200W

400W

Continuous Power

200W

400W

Surge Power

400W

800W

Output Waveform

Modified Sine Wave

AC Output voltage

115V +/- 10%

AC Output amps (up to)

1.8A

3.6A

DC Input Voltage

10V to 15V +/-.5v

DC Input Amps (up to)

20A 40A

Efficiency

>85%

No load current

<0.3A <0.6A

Cooling Fan

No

Yes

Short Protection

Yes

Yes

Soft- Start

Yes

High Voltage Protection

Yes

Low Battery Alarm (Bat’ Saver)

11.9VDC

Low Battery Shutdown (Bat’ Saver)

11.7VDC

Low battery Alarm

10.5VDC +/- .5VDC

Low Battery Shutdown

10VDC +/- .5VDC

Reverse Polarity Protection (By Fuse)

Yes

Operating environment temperature

-15 to 50° Celsius or 5 to 122° Fahrenheit

External Fuse

25A 40A

Recommended User Supplied

25A 40A

ABYC E-11 Compliant Fuse

ProMariner Part No. for Recommended
User Supplied ABYC E-11 Compliant Fuse

Amperage

5 - 70 amps 30 amp 40 amp

AGU Fuses for TruePower Models

88103 88530 88540

Single Position

AGU Fuse Holder

AGU Fuse

for 400w

AGU Fuse

for 200w

Inverter Features

The TruePower inverter comes standard with a Ground Fault Circuit Interrupter
(GFCI) protected Dual AC outlet which can protect the user against hazardous
electrical shock that could be caused by dampness, water spray, or worn cables.

Bat’ Saver- mode allows the user to protect from draining down the entire power of
the engine start battery, and shuts the inverter off when the battery reaches a threshold
of 11.7 volts allowing you to still start your boat or vehicle.

Soft Start, Noise Filtered Technology- progressively increases the output voltage to
start heavy loads, with minimal or no interference.

TruePower performance features include:

- Internal Conformal Coating for Anti-Corrosion
- Soft Start and Noise Filtered Technology
- Bat’ Saver Mode – 200 to 1200 watt Models
- True Rated Continuous Power
- Hi-Surge Ratings for Demanding Loads
- Heavy Duty Marine/Industrial Construction
- Constructed to UL 458
- Meets the Requirements of ABYC E-11 Marine
- Highly Visible Power & Fault LED Indicators

TruePower Inverters are protected by a variety of features including:

- GFCI AC Outlet Safety Protected
- Input Polarity Protection
- Low Battery Alarm
- Low Battery Shutdown
- Overload Protection
- Output Short Circuit Protection
- Thermal Protection
- Over Voltage (15 VDC) Protection

Note: These inverters may not be suitable for use with some fluorescent lighting, halogen lights or
other inductive loads. If you wish to run such an item, plug it in to one of the inverter outlets and plug
in a small non-inductive load bearing item such as a low wattage light bulb into the other outlet.

Mounting your Inverter

IMPORTANT: ALWAYS PLACE THE INVERTER IN AN ENVIRONMENT WHICH IS:

(A) WELL VENTILATED
(B) NOT EXPOSED TO DIRECT SUNLIGHT OR HEAT SOURCE
(C) OUT OF REACH FROM CHILDREN
(D) AWAY FROM WATER / MOISTURE, OIL OR GREASE
(E) AWAY FROM ANY FLAMMABLE SUBSTANCE
(F) DO NOT INSTALL DIRECTLY ABOVE OR BELOW BATTERIES

Advertising