Maintenance, Using the prosafe one monitor continued – ProMariner ProSafe One User Manual

Page 6

Advertising
background image

4

7

I n s t a l l a t i o n G u i d e l i n e s

M a i n t e n a n c e & A c c e s s o r i e s

Typical Hookup for Single 30 Amp/120 Volt Inlet

Typical Hookup for Dual 30 Amp/120 Volt Inlets

Optional Accessories

Part No. ProSafe One System Components
22079

ProSafe One main unit - single shore cord

22080

ProSafe One main unit - dual shore cord

22075

ProSafe One remote display

22110

1 meter isolator sense cable

22111

4 meter isolator sense cable

22112

7 meter isolator sense cable

22113

10 meter isolator sense cable

22115

3 meter remote extension cable

22033

30 amp ProSafe galvanic isolator

22066

60 amp ProSafe galvanic isolator

Call your Professional Mariner Dealer or representative for the monitor best suited for
your application.

We are committed to customer satisfaction and value your business. If at any time during
the warranty period you experience a problem with your new ProSafe One Ground Wire
and Galvanic Isolator Monitor, call us at 1-800-824-0524 for technical support.

If a replacement unit is needed, during warranty period ProMariner will ship a replacement
at no cost with a prepaid UPS shipping label for the original unit to be returned.

Maintenance

The ProSafe One Ground Wire and Galvanic Isolator Monitor is self contained and should
need no service. Periodically check all connections are tight, clean and free of moisture.

Using The ProSafe One Monitor Continued

Note: With any of the above faults present, and because of the possibility of high AC voltage
on the bonding system, it is highly recommended that the vessel's shore cord be disconnected
until a marine technician can determine and repair the fault.

To Silence the Audible Alarm:
In the event of a "FAIL" condition, if it is preferred to be able to use your 110/220 volt systems
without the presence of the audible alarm it can be silenced by holding the "TEST" button until
the alarm silences. The alarm will stay silent while leaving the "FAIL" LED illuminated. This does
not rectify the "FAIL" condition, and it is imperative that the reverse polarity condition, ground
wire or isolator be checked for a fault and the fault be repaired.

PN. 22079

Single AC Monitor

NOTES:
1. PN. 22115 Remote Monitor Extension Cable - 3 meters

N

6 ga.

PN. 22033

30 amp isolator

L1

MAIN Breaker

Green

Blue
Brown

PN. 22113 - 10 meter

PN. 22112 - 7 meter

PN. 22110 - 1 meter Isolator Cable
PN. 22111 - 4 meter

PN. 22075
Remote Display

NOTE 1

30 amp

ProSafe1

Shore Cable

Green

Bulkhead
Connector

AC Ground Bus

30 amp

30 amp

AC Ground Bus

MAIN Breaker

L1

Brown
Blue

Green

6 ga.

PN. 22066

60 amp isolator

L2

Blue

Green

Brown

MAIN Breaker

PN. 22080

Dual AC Monitor

NOTE 1

PN. 22075
Remote Display

PN. 22111 - 4 meter

PN. 22110 - 1 meter Isolator Cable

PN. 22112 - 7 meter
PN. 22113 - 10 meter

N

N

NOTES:
1. PN. 22115 Remote Monitor Extension Cable - 3 meters

ProSafe1

Shore Cable