Power supply features, Low voltage psu (lvp) specification, Standard psu – Raytec RAYMAX 300 PLATINUM User Manual

Page 7: Premium psu-pr, Pulsed psu - pu, Premium timer psu-prt, Infra-red and white-light series psu

Advertising
background image

7

Power Supply features

STANDARD PSU

• Adjustable photocell

• Adjustable power

• Telemetry input

PReMIUM PSU-PR

• Adjustable photocell

• Adjustable power

• Telemetry input

• Photocell following contact, volt

free relay contact - normally open

(day) to normally closed (night)

• 12V DC output @ 1.5A

PULSeD PSU - PU

• Analogue version

• TTL version

• No photocell

• Adjustable power

• 12V DC output @ 1.5A

• Synchronised with camera

PReMIUM TIMeR PSU-PRT

• Adjustable photocell

• Adjustable power

• Telemetry input

• Photocell following contact, volt

free relay contact - normally open

(day) to normally closed (night)

• 12V DC output @ 1.5A

• Timer function

300

200

150

100

50

25

Input

x

24V AC/DC

x

24V AC/DC

12/24V AC/DC

12/24V AC/DC

Fuse

x

5A

x

5A

3A

3A

Typical Output

(Infra-Red)

x

4.4A @ 13.5V

x

2.4A @ 13.5V

1A @ 13.5V

0.5A @ 13.5V

Typical Output

(White-Light)

x

4.2A @ 13.5V

x

2.8A @ 13.5V

1.4A @ 13.5V

0.7A @ 13.5V

Adjustable

Power

x

10% - 100%

x

10% - 100%

10% - 100%

10% - 100%

Weight

x

1.85 kg

(4.1lbs)

x

1.65 kg

(3.6lbs)

0.9 kg

(2lbs)

0.8 kg

(1.8lbs)

Dimensions

L x W x D

x

160 x 160 x 81mm

(6.3 x 6.3 x 3.2”)

x

160 x 160 x 81mm

(6.3 x 6.3 x 3.2”)

130 x 130 x 60mm

(5.1 x 5.1 x 2.4”)

130 x 130 x 60mm

(5.1 x 5.1 x 2.4”)

Drilling

Dimensions

x

4 x M4 holes

@ 145 x 123mm

(5.7” x 4.8”)

x

4 x M4 holes

@ 145 x 123mm

(5.7” x 4.8”)

4 x M4 holes

@ 113 x 113mm

(4.4” x 4.4”)

4 x M4 holes

@ 113 x 113mm

(4.4” x 4.4”)

Low Voltage PSU (LVP) Specification

INfRA-ReD AND WHITe-LIGHT Series PSU

(excluding Platinum and Covert Series)

NOTe: ensure operating voltage is correct for unit being installed.
DO NOT INPUT MAINS VOLTAGe INTO LOW VOLTAGe PSUs.

!

Advertising