ROTRONIC AC3011 User Manual

V+ u, Slave hf5, Masterbox ac3011

Advertising
background image

12

.0

94

4.0

00

2

12

.0

94

4.0

00

2

ROTRONIC AG, CH-8303 Bassersdorf

Tel. +41 44 838 11 44, www.rotronic.com

ROTRONIC Messgeräte GmbH, D-76275 Ettlingen

Tel. +49 7243 383 250, Fax +49 7243 383 260, www.rotronic.de

ROTRONIC SARL, 56, F - 77183 Croissy Beaubourg

Tél. +33 1 60 95 07 10, www.rotronic.fr
ROTRONIC Italia srl

,

I- 20157 Milano

Tel. +39 2 39 00 71 90, Fax (+39) 02 33 27 62 99, www.rotronic.it

ROTRONIC AG, CH-8303 Bassersdorf

Tel. +41 44 838 11 44, www.rotronic.com

ROTRONIC Messgeräte GmbH, D-76275 Ettlingen

Tel. +49 7243 383 250, Fax +49 7243 383 260, www.rotronic.de

ROTRONIC SARL, 56, F - 77183 Croissy Beaubourg

Tél. +33 1 60 95 07 10, www.rotronic.fr
ROTRONIC Italia srl

,

I- 20157 Milano

Tel. +39 2 39 00 71 90, Fax (+39) 02 33 27 62 99, www.rotronic.it

Bitte lesen Sie diese Kurzanleitung genau durch, bevor Sie die Box installieren.

Kann verwendet werden mit

• AirChip 3000 Geräte die ein RS-485 Anschluss besitzen

• Dockingstations für den HygroLog HL-NT

• Alle alten Produkte welche ein RS-485 Anschluss besitzen (z.B. HygroLog NT)

Allgemeine Beschreibung

Es können bis zu 64 RS-485 Slave Geräte am AC3011 angeschlossen werden.
Der AC3011 besitzt eine IP jedoch keine RS-485 Adresse. Das Gerät zählt nicht als eines
der Geräte im RS-485 Netzwerk.

Hinweis
1. Die Nutzung des AC3011 erfordert einen PC mit der Software HW4 Version 2.4.0 oder

höher. Die HW4 Software beinhaltet ein Ethernet-Konfigurations-Tool, welches benützt
werden kann um TCP/IP Einstellungen des AC3011 kompatibel mit den LAN (zu welchem
der PC angeschlossen ist) zu machen.

2. Die Masterbox AC3011 erlaubt es AirChip 3000 und alte Geräte im selben RS-485

Netzwerk zu mischen, solange alle Geräte dieselbe Baudrate (19200) verwenden.

Achtung
Die Masterbox ist in der Software HW4 nich ersichtlich. Es werden nur die Slaves angezeigt.

Please read these short instructions carefully before installing the box.

Use with

• Any AirChip 3000 device that has a RS-485 port

• Docking stations for the HygroLog HL-NT

• Any legacy device that has a RS-485 port (e.g. HygroLog NT)

General Description

Allows connecting up to 64 RS-485 slave devices to an Ethernet port (PC or LAN).
The AC3011 has an IP address but no RS-485 address and does not count as one of the
devices on the RS-485 network.

Important
1. Use of the AC3011 requires a PC with the HW4 software version 2.4.0 or higher. The

HW4 software includes an Ethernet Configuration Tool that can be used to make the
TCP/IP settings of the AC3011 converter compatible with the LAN to which the HW4 PC is
connected.

2. The AC3011 converter allows mixing both AirChip 3000 and legacy devices within the

same RS-485 network as long as all devices use the same Baud rate (19200)

Note
The Masterbox is not visible in HW4 software. Only the Slaves can be seen.

KUrzBeDIeNUNGsANleItUNG

sHort INstrUctIoN mANUAl

MASTERBOX AC3011

MASTERBOX AC3011

Po

wer

terminal

Description

K1-1

GND

K1-2

V +: 12 to 24 VDC

K1-3

sP

eI

sUNG

Klemme

Beschreibung

K1-1

GND

K1-2

V +: 12 to 24 VDC

K1-3

rs

-485

terminal

Description

K3-4

D –

K3-3

D +

K3-2

GND

K3-1

V +

rs

-485

Klemme

Beschreibung

K3-4

D –

K3-3

D +

K3-2

GND

K3-1

V +

Installation in the rs-458 Network

Installation im rs-485 Netzwerk

Installation
1. The master box can be mounted with the delivered screws on a wall.
2. If there is a TS35 DIN top-hat rail available, the transmitter can be

clipped on to the top-hat rail directly with the help of the mounting
kit AC5002 (available as optional extra). For this, the DIN holders
are screwed directly on to the predrilled holes in the transmitter.

electrical installation and connections
The RJ-45 connector is accessible without having to open the AC3011 enclosure.

ROTRONIC Instruments (UK) Ltd, West Sussex, RH10 9EE , UK

Phone +44 1293 571000, www.rotronic.co.uk

ROTRONIC Instrument Corp, NY 11788, USA

Phone +1 631 427-3898, www.rotronic-usa.com

ROTRONIC South East Asia Pte Ltd, Singapore 339156

Phone +65 6294 6065, www.rotronic.com.sg

ROTRONIC Shanghai Rep. Office, Shanghai 200233, China

Phone +86 40 08162018, www.rotronic.cn

ROTRONIC Instruments (UK) Ltd, West Sussex, RH10 9EE , UK

Phone +44 1293 571000, www.rotronic.co.uk

ROTRONIC Instrument Corp, NY 11788, USA

Phone +1 631 427-3898, www.rotronic-usa.com

ROTRONIC South East Asia Pte Ltd, Singapore 339156

Phone +65 6294 6065, www.rotronic.com.sg

ROTRONIC Shanghai Rep. Office, Shanghai 200233, China

Phone +86 40 08162018, www.rotronic.cn

montage
1. Die Masterbox wird mit den mitgelieferten Schrauben an eine Wand

montiert.

2. Die Masterbox kann bei vorhanden DIN-Hutschienen TS35 unter

Mithilfe des Montagekit AC5002 (optional erhältlich) direkt auf die
DIN Hutschiene aufgeschnappt werden. Hierzu werden die DIN-
Halterungen direkt auf die vorgebohrten Löcher des Transmitters
geschraubt.

elektrische Installation und Anschlüsse
Der RJ-45 Anschluss ist zugänglich ohne den AC3011 zu öffnen.

AC3021

AC3021

AC3021

V+

U

DC

GND

RS485+

RS485-

Master

AC3011

no RS485

Address

Slave

HF5

Addr. 1

PC

with

HW4

Slave

HF5

Addr. n...64

Ethernet

AC3021

AC3021

AC3021

V+

U

DC

GND

RS485+

RS485-

Master

AC3011

no RS485

Address

Slave

HF5

Addr. 1

PC

with

HW4

Slave

HF5

Addr. n...64

Ethernet

Advertising