3.0 ELECTRICAL INSTALLATION

3.1 Voltage Output Units

The Model 227 voltage output transducer is supplied with a 6ft. multiconductor
cable, Bayonet style connector, or D-Sub style connectors. The voltage output
is either 5 VDC FSO or 10 VDC FSO. Diagram 2 shows electrical connection
wiring for voltage output transducers, and the excitation required.

3.2 Current Output Units

The Model 227 is a two-wire loop-powered 4 to 20mA current output unit and
delivers rated current into any external load of 0-800 ohms. The Model 227 is
available with 6ft. of multiconductor cable, Bayonet style connector or D-Sub
style connectors. Diagram 3 shows electrical connection wiring for current
output transducers.

Note 1: The transducer case and integral connector Shell are electrically connected.

The power supply must be a DC voltage source with a voltage range between
10 VDC and 30 VDC measured between the + and - terminals. The unit
is calibrated at the factory with a 24 VDC loop supply voltage and a 250 ohm
load.

9 PIN

15 PIN

CABLE

BAYONET

D-SUB

D-SUB

CONNECTION

WIRE

PIN

PIN

PIN

+ EXCITATION

RED

A

4

7

+ OUTPUT

GREEN

B

1

2

– OUTPUT

WHITE

C

8

12

– EXCITATION

BLACK

D

9

5

CASE GND

DRAIN

SHELL

SHELL

SHELL

9 PIN

15 PIN

CABLE

BAYONET

D-SUB

D-SUB

CONNECTION

WIRE

PIN

PIN

PIN

+ EXCITATION

RED

A

4

7

– EXCITATION

BLACK

D & B

9

5

CASE GND

DRAIN

SHELL

SHELL

SHELL

Diagram 2

CONNECTOR PIN WIRING FOR VOLTAGE TRANSDUCERS

EXCITATION:

10-30 VDC FOR 0.2 TO 5.2 VDC and 0 to 5 VDC
13-30 VDC FOR 0.2 TO 10.2 VDC and 0 to 10 VDC

Diagram 3

CONNECTOR PIN WIRING FOR CURRENT TRANSMITTERS

Minimum Supply Voltage = 10 + 0.02 x Loop Resistance
Maximum Supply Voltage = 30 + 0.004 x Loop Resistance

Note 1: Model 227 can be wired as a 3-wire device by connecting – OUTPUT and

–EXCITATION and drain wire to a common ground. However, accuracy may be
reduced due to increase in resistance.

2.4 Venting

Model 227 gauge or compound transducers are vented through the
electronics housing.

and