13 of 36

Figure 1: Pipe Sizing Guide

Pipe Sizing Guide

Pipe Size

Flow-Steel Pipe

Flow-PVC Pipe

1/2 2 2

3/4 5 5

1 10 10

1 1/4

20

20

1 1/2

30

30

2 50 55

2 1/2

100

100

3 160

160

4 320

320

6 900

1000

8 2000

2100

10 3500

3700

12 5000

5800

Based on 10’ head loss/100’ of pipe (new pipe) — open piping systems. A safety factor of 15
to 20% should be added based on local conditions.