SETTINGS AND ADJUSTMENTS

SECTION 4-20

Drive Belt Replacement Or Adjustment

COMPARE MEASURED FORCE TO
RECOMMENDED FORCE

Compare the deflection force measured, to the

value shown in the table.

For new belts the value for run-in should be used.

For belts, which have been running two days or

more, use the values for normal running.

ADJUST THE BELT TENSION
Adjust the sliding motor base to increase the belt tension by turning

the adjusting screws clockwise.

When the tension has been increased significantly, recheck it using

the procedure just described.
Repeat the process of adjustment and tension checks until the

allowable deflection is achieved while the deflection force is within

the range shown in the table.

Tension new drives at the maximum deflection force

recommended.

Check the tension at least two times during the first two days of

operation. There is normally a rapid decrease in tension until the

belts are run in.

Check the tension periodically after the first day of operation and

keep the tension in the recommended range-

The correct operating tension for a V-belt drive is the lowest

tension that allows NO belt slip under peak load conditions.

If the deflection is more than the specified deflection at the

recommended force, tighten the belts. If the deflection is less than

the specified deflection at the recommended force, loosen the belts.

TIGHTEN THE MOTOR BASE BOLTS

Tighten down the motor mounting bolts.