background image

GRN4-610

Chapter 2: Functional Description

27 of 73

Time setting menu

Illustration:

Operation panel time setting menu

End holding: the ram reaches end position and delay time
Standard push: When the ram pushes, this action lasts 30 seconds and
then will has a 1 second pull action. So the 30 seconds is standard push
time and the 1 second is standard pull.
Standard pull: See above.
Pulse push: When the ram moves to 700mm point before end position, it
will act as this rule, pushes 3 seconds and stop 1 second, so the 3 seconds
is pulse push and 1 second is pulse stop.
Pulse stop: See above.