Cycle program – Timeguard TR 672 top User Manual

Page 9

Advertising
background image

8

Effect of the cycle program:
The clocking and pause times can be set separately. The settable times
are max. 99 minutes and 59 seconds. The cycle program has the effect
that between two programmed times, day of week start and day of
week finish, the cycle program is active. The cycle program always
begins with a switch on. 16 memory locations are available to you.
The symbol flashes when the cycle program is active.

Viewing the cycle times:
Possible in the menu Cycle only!
N.B.:

If two cycle times are

programmed in which the start and
finish times overlap, it is always the
cycle time that starts first that is
executed.
Example:

Cycle time 1, programmed

from: Mo to Thu
Cycle time 2, programmed from: Tue
to Fri. Only cycle time 1 is effective,
cycle time 2 is not accepted.

Brightness variations at lighting
installations may arise in the
cycling mode. In this case actions
to reduce these effects have to be
taken (for example reduction of
the load or extension of the cycle
time). More than five switching
operations per minute are not
admissible without additional
EMC interference measures.

Select by pressing the key Cycle.
Store your selection by pressing the key.
Set cycle start by pressing the keys or .
Store your selection by pressing the key.
Set cycle duration (Min./sec.) by pressing the
keys or .
Store your selection by pressing the key.
Set cycle pause (Min./sec.) by pressing the keys

or .

Store your selection by pressing the key.
Set cycle finish by pressing the keys or .
Store your selection by pressing the key.

Cycle program

Cyclically recurring time functions within the scope of a timer, e.g.
slow flashing indicator, water treatment, advertisement lighting

duration

pause

Example cycle start:
Monday 7.30 h ON

Example cycle finish:
Friday 16.30 h OFF

Advertising