3. INSTALLATION

Before proceeding further fit the lamp to the flood light. To do this remove the 4 screws
retaining the front glass and frame using a suitable cross point or flat blade screwdriver
referring to Fig. 3. Remove the frame and glass being sure to retain the screw sealing rings
and the frame gasket.

Remove the spiral lamp from its box, ensure the lamp holders within the flood light are in the
open position (see Fig. 4a). Insert each end of the lamp into the lamp holders and rotate the lamp
through 90º so that the lamp holders are as shown in Fig. 4b.

After choosing a suitable location (see previous section) install the unit as follows:

Remove the wiring box cover by unscrewing the 4 retaining screws (Fig. 5) and remove the
cover being careful to retain the 4 screw sealing rings and the cover gasket.
The unit is suitable for connection to a 230 V ac 50Hz electricity supply. It is suggested that
3-core round flexible cable of 1mm

2

gauge is used. An isolating switch should be installed to

switch the power to the unit ON & OFF. This allows the sensor to be easily switched off when
not required or for maintenance purposes and to invoke manual override (see section 6).

Mark the position of the 2 fixing holes (see Fig. 6).
Drill the holes. Insert the wall plugs into the holes if necessary and drive the 2 screws in until
the back of the heads are approx. 3mm clear of the wall.
BEFORE PROCEEDING, slacken off the cable gland and pass the cable through it.
Fix the mounting bracket to the wall by pushing the larger part of the keyhole over the screw
head and then sliding the bracket downwards so that the screw sits at the top of the narrow
section of the keyhole. Tighten the fixing screws.

*** IMPORTANT ***

Switch off the electricity at the consumer unit by removing the relevant fuse or switching

off the relevant circuit breaker before proceeding with the installation.

Fig. 5

Fig. 6

wIRING BOx COvER

MOUNTING BRACkET

OPEN

ClOSED

Fig. 3

Fig. 4a

Fig. 4b

FRONT GLASS REMOvAL

LAMPHOLDER POSITION

4 x Retaining Screws

4 x Retaining Screws

Fixing Keyhole