MANUAL OvERRIDE MODE
The light can be switched on for longer time periods by use of the Manual Override Mode.
This can be activated at night by using the internal wall switch or circuit breaker.

Switch the internal wall switch/circuit breaker twice (on/off once) within 1/2 to 2 seconds.
The unit will now illuminate continuously until it is switched back into Auto Mode.

To get switch the unit back into Auto Mode, switch the internal wall switch/circuit breaker
off for 10 or more seconds and then back on again. The unit will return to Auto Mode.

5. TECHNICAL SPECIFICATIONS

Detection Range

Detection Angle

Power Supply

Maximum Switchable Lamp Load

Time On Adjustment

Dusk Level Adjustment

Environmental Protection

EC Directives

Up to 12 metres

Up to 160º

230 v AC ~ 50Hz

36w Low Energy Spiral bi-pin tube*

30 seconds - 7 minutes approx.

Day & night or night only operation

IP44 (suitable for outdoor use)

Conforms to 73/23/EEC, 89/336/EEC

If you experience problems refer to

Troubleshooting Guide.

If problems still persist, do not

immediately return the unit to supplier.

Telephone the Timeguard Customer

Helpline

020 8450 0515

Qualified Customer Support Co-ordinators will be

on-line to assist in resolving your query.

* Should you experience difficulty in obtaining replacement

lamps, these are available from Timeguard Limited, please ring

the helpline number below.