Timeguard SLW89 User Manual

Page 5

Advertising
background image

SECTION THREE

INSTALLATION

After choosing a suitable location (see previous section) install the unit as follows:

The unit is suitable for connection to a 230 V ac 50Hz electricity supply. It is suggested that
3-core round flexible cable of 1mm

2

gauge is used. A isolating switch should be installed to

switch the power to the unit ON & OFF. This allows the sensor to be easily switched off
when not required or for maintenance purposes.

Remove the diffuser using a terminal screwdriver to release the clips on both sides
(diagram E).
Remove the connection cover (diagram F)
Ensure the unit is in an upright position with the sensor module at the bottom.
Mark the position of the fitting holes.
Drill the holes. Insert the rawl plugs into the holes.

PIERCE & PASS THE CABLE THROUGH THE GROMMET BEFORE PROCEEDING.

Attach the mounting plate to the wall using suitable screws. Do not overtighten the
mounting screws as this could damage the mounting plate. If using a power screwdriver,
use the lowest torque setting.

CONNECTION
Pass the mains supply cable around the back of the lampholder for ease of wiring.

Connect the cable to the terminal block on the unit as follows (see connection diagram):

NEUTRAL (Blue)

N

EARTH (Green/Yellow)
LIVE (Brown)

L

Ensure that the connections are secure.
Re-attach the connection cover.
Install the lightbulb (not supplied).
Fit the diffuser back onto the main body of the unit, ensuring it clicks firmly in place.

*** IMPORTANT ***

Switch off the electricity at the fuse box by removing the relevant fuse or

switching off the circuit breaker before proceeding with the installation.

CONNECTION DIAGRAM

N

L

E

E

L

N

L

1

Mains
Supply

Isolation Switch