Timeguard SLW89 User Manual
Page 7
If you experience problems refer to Troubleshooting Guide.
If problems still exist, do not immediately return the unit to store.
Telephone the Timeguard Customer Helpline
020 8450 0515
Qualified Customer Support Co-ordinators will be on-line to assist in resolving your query.
SECTION FIVE
TECHNICAL SPECIFICATIONS
Detection Range
Detection Angle
Power Supply
Maximum Switchable Load
Lamp Type
Time On Adjustment
Dusk Level Adjustment
Environmental Protection
EC Directives
Up to 8 metres
110º
230 V AC ~ 50Hz
500W including fitted bulb
230V 60W (max) GLS ES
5 seconds - 5 minutes
Day & night or night only operation
IP44 (suitable for outdoor use)
Conforms to 73/23/EEC, 89/336/EEC
At this position, the unit should become operative at approximately the same level of
darkness each evening. Observe the operation of the unit. If the unit is starting to operate
too early (ie. when it is quite light), adjust the control slightly anti-clockwise. If the unit starts
to operate too late (ie. only when it is very dark), adjust the control slightly clockwise.
Continue to adjust until the unit operates as desired.
MASKING THE SENSOR LENS
To reduce the sensor coverage, preventing detection in unwanted areas, mask the sensor lens
using electricians tape or similar (see diagram D). For your information, the top section of
the lens covers long range detection, the bottom covers short range. Similarly, the left and
right lens sections cover the left and right detection areas respectively.
Not suitable for energy
saving lamps