Installation – Timeguard MTLW3000 User Manual

Page 5

Advertising
background image

1

4

Installation

IMPORTANT

Switch off the electricity at the fuse box by removing the

relevant fuse or switching off the circuit breaker before

proceeding with the installation.

After choosing a suitable location (see previous section)

install the unit as follows:
The unit is suitable for connection to a 230 V ac 50Hz

electricity supply. It is suggested that 3-core round

flexible cable of 1.5 sq. mm gauge is used. An internal

switch should be installed to switch the power to the

unit ON & OFF. This allows the sensor to be easily

switched off when not required or for maintenance

purposes.
This product is designed to be mounted on walls or

under eaves, see diagram E. The sensor can be rotated

through 180 degrees to direct detection where

required, consider your location carefully before

installation.
Remove the unit from its packaging.
Unscrew the wiring box fixing screw shown on diagram

F. This screw is captive, do not fully remove.
Detach the wiring box from the Sensor body.
Using the wall plate as a template, mark the position

of the fitting holes.
Drill the holes. Insert the wall plugs into the holes.
PIERCE & PASS THE CABLE(S) THROUGH THE

GROMMET(S) BEFORE PROCEEDING.
It is recommended that the grommet is pierced with a

screwdriver to ensure a better seal.
Attach the mounting plate to the wall using screws

provided. Do not overtighten the mounting screws as

this could damage the unit. If using a power

screwdriver, use the lowest torque setting.
This unit features an installation aid. Simply hang the