Connection
Connect the mains supply cable to the terminal block

on the unit as follows (see connection
diagram):
NEUTRAL (Blue)

N

EARTH (Green/Yellow)
LIVE (Brown)

L

Connect the cable from the lighting load to the terminal

block on the unit as follows (see connection diagram):
NEUTRAL (Blue)

N

EARTH (Green/Yellow)
LIVE (Brown)

L1

Ensure that all connections are secure.
Ensure the terminal block is attached to its mounting

posts in the sensor body.
Un-hook the sensor unit from the wall plate and

re-attach to the wall plate box as follows:-
Ensure no wires are trapped.
Align the sensor centrally over the wiring box and

attach the top edge of the sensor to the wall plate. see

diagram I. There will be an audible click indicating that

the top clips are located into the wall plate.
Slowly rotate the sensor body downwards and and

ensure no wires are trapped, the lower edge of the

unit will locate into the wallplate.
Fully tighten the fixing screw. See diagram F.
Installation is complete.
Connection
Diagram

Sensor onto the wall plate by use of the clip

arrangement on the wall plate. See diagram H. This

allows you to use your hands to hold the screwdriver,

and install the incoming cables with ease.
Connect the incoming and outgoing cables as follows.

Isolation switch

Load

Mains

supply