Trouble shooting – Timeguard HF1 User Manual

Page 7

Advertising
background image

6

6. Trouble Shooting:

1) When powered on (after the 60 seconds warm up) the sensor
goes into the auto mode. Please open the front cover and turn the
TIME setting to its minimum and the LUX setting to its maximum
in order to test.
2) Walk in front of detector until light comes on. This checks the
operation of the detector and the field of view.
3) Turn the TIME and LUX to the desired positions.
4) To switch the light permanently ON (4 hours max), switch OFF
and ON twice in rapid succession within in the range of 0.5 sec
to 2 sec. This will change the HF1 from auto mode to manual
override mode.
5) The sensor will automatically turn off after 4 hours or by switching
power switch OFF for 2 sec and ON again.
6) The LED will flash 3 times when sensor goes into auto mode.
Note: If LED is still on, it means it is in override mode;
make sure to switch off power for more than 2 sec.
When in override mode, the LED will be on permanently.

Malfunction Cause

Solution

Sensor without power Fuse blown,

Replace fuse and switch ON

not switched ON

mains switch. Check supply

with voltage tester

Short circuit

Check connection

Sensor does not

Fuse blown

Replace fuse and check

switch ON

connection if necessary

Bulb blown

Replace bulb

Lux setting in night time

Readjust Lux setting

mode during daytime

operation

Sensor does not

Detect continued

Check detection area

switch OFF

movement

in detection range

Permanent light ON

Switch off permanent light

Sensor switch keeps

Curtains, pets, etc…

Check detection area

switching ON and OFF

Advertising