Introduction, 2 installation, 1 product range covered – Timeguard TPSL04 User Manual

Page 8

Advertising
background image

Complies with

EN60669

IP55

weatherproof

rating

Tough, durable

impact resistant

housing

Bottom cable entry with

cut to size grommet

5 x 20mm

cable entries

Cut to size

blind grommet

2 x drain hole cut

outs (if required)

2 x Earth

terminals

2 x 8 fixing

holes

5 x 20mm

conduit

knockouts

1 Product Range Covered

TPS101

Single Socket Outlet Unit

Single Gang

Back Box

(TPS101, TPSL01,

TPSL02, TPSL03,

TPSL04)

Easy lift

spring back

lid cover

Suitable

for all BS

13 amp

plugs

5 x 20mm

knockout

cable entries

Special IP55

weatherproof

seal

IP55

weatherproof

rating

Tough,

durable

impact

resistant

housing

Introduction

PowerSeal products (shown here) are a

cost effective range of switches and socket

outlets designed for external use with the

necessary IP (water and dust protection)

rating established by an independent test

authority.

The socket outlets cannot be used while it is

raining since there is no protection while a

plug is in the socket but users would not be

operating most commonly available DIY and

gardening equipment in the rain.

The tough, impact resistant casings of this

range give good physical protection in

outdoor locations.

Water may accumulate outside the sealed

area. To ensure full safety wipe the face of

the socket before use.

TPS201

Double Socket Outlet Double Gang Unit

TP203

20A Switch and 13A Socket Outlet Double Gang Unit

Double Gang Back Box

(TPS201, TP203)

Easy lift spring

back lid covers

Easy lift spring

back lid cover

Suitable for

all BS 13 amp

plugs

Suitable for

all BS 13 amp

plugs

Tough, durable

impact resistant

housing

Tough, durable

impact resistant

housing

8 x 20mm

knockout

cable entries

8 x 20mm

knockout

cable entries

Special IP55

weatherproof

seal

Special IP55

weatherproof seal

IP55 weatherproof

rating

IP55 weatherproof

rating

Rocker

Cut to size

blind grommets

4 x drain hole cut

outs (if required)

Switch rocker should be

removed by prising off with

a flat screwdriver. Use a

piece of card to prevent

marking the the unit.

4 fixing holes

8 x 20mm conduit

knockouts

2 x Earth

terminals

2 Installation

This product must be installed in accordance with the appropriate
Building and Wiring Regulations.
In all cases if there is a doubt as to how to proceed with an
installation consult a qualified electrician, your Local Authority’s
Building Control Department or the Timeguard Helpline
(020 8450 0515).
For the switches the screws holding the case halves together are
located beneath the rocker(s) (front plate switch actuator(s)).
To remove the rocker first press rocker inwards at the blind grommet
end, then, removing hand from there, force fingers as far as possible
between the opposite end of the rocker and the case, pulling the
rocker outwards. The rocker will unclick at it’s pivot point.
If it is not possible to exert enough force by hand, use the
technique shown at the foot of the previous page.

2.1 Cable Entry

Try to avoid siting the units in areas where there is direct sunlight for
any length of time.
Cable entry can be made via conduit into any of the 5 (8 for the
double socket TPS201 and switch socket TP203) knock outs on the
top, bottom, sides or back of the back box. In all cases ensure there
is a drain hole at the lowest point in the attached conduit system.

The knock out outline should be heavily scored with a sharp knife
before tapping out.
The appropriate sealing washers for the conduit in use must be
used to maintain the IP rating. The use of any knock outs apart
from the one(s) at the bottom requires that the lower drain hole(s)
on the back box is opened and the IP rating may well be reduced.
The blind grommets may be used for cable entry at the bottom
20mm hole(s). They must not be used in any other position
(including the rear) or the IP rating may be severely prejudiced.
The blind grommets should be pierced centrally to give an
undersize hole of a similar shape to the cable cross section.

2.2 Fixing Back Box

Drill 2 holes (4 for the double socket TPS201 and switch and socket
TP203) according to the dimensions given on the rear of the back
box. Fix with round head no. 8 woodscrews or equivalent using
wall plugs if necessary. The length of the screw will depend on the
surface being fixed to, for example fixing to roughcast would
require a longer screw than fixing to brickwork.

2.3 Connecting Cables

Allow sufficient excess cable to wire up the socket(s) or switches
but not too much to make it difficult to close the front plate onto
the back box.

TPSL02

Double Switch

(single gang size)

TPSL01

Single Switch

TPSL03

Single Bell

Push Switch

TPSL04

20AX DP Switch

Rocker

Rockers