Installation – Timeguard TPT44 User Manual

Page 3

Advertising
background image

2

Installation

We recommend this unit be fitted by a

qualified electrician.

Install in accordance with wiring and current

building regulations.
Please read the instructions carefully. If in doubt,

contact the Timeguard Helpline 020 8450 0515.

The TPT44 underfloor heating controller is designed

to fit onto either a BS4662 recessed single box or a

BS5733 surface mount single box. The minimum box

depth required is 32mm. The ideal mounting height

is at eye level for the shortest person who is likely

to programme the unit. For details of the installation

of the temperature probe and heating cable or mat

see the Thermolay instruction leaflet.
Switch OFF the mains to the controller.

Remove the thermostat surround by pulling

forward on the surround. Use a small screwdriver as

a lever to remove the surround when the thermostat is

fixed on the wall. Cut the cable tails of the temperature

probe and heating mat or cables to length and strip

sleeving and insulation as required. Identify the wires

and locate according to figure 1. Supply cable with

a minimum of 2.5mm

2

must be used. Tighten the

screw terminals onto the wires and form the cables.

Ensure that the link shown between terminals 2

and 3 in Fig. 1 is in place. Offer the unit up to the

wall box forming the cables as required, finally locating

and tightening up the fixing screws supplied.

Snap the surround back into position.

To test the unit is operating set the temperature to

30ºC as described in ‘Manual Temperature Setting A.