Manual Temperature Setting

A. Temporary temperature override.

1. Press ’+’ or ’–’. The ’ ’ indicator and the

temperature flash.

2. Press the ’+’ or ’–’ key to set the temperature.
3. Press ’Set’ key once to confirm and the ’ ’

indicator flashes every 3 seconds. It will stay in

this Temporary temperature override mode until the

next change from Comfort to Set-Back or vice versa.

4. To exit the temporary override at any time

press ’Set’ again.

B. Hold function in hours.

1. Press ’+’ or ’–’, the ’ ’ indicator and the

temperature flash.

2. Press ’+’ or ’–’ key to set the temperature.
3. Press ’Prog’ key, ’1H’ indicator displayed.

4. Press ’+’ or ’–’ key to set the number of running

hours from 1 to 24. The ’ ’ indicator flashes

every 3 seconds.

5. To cancel this mode press the ’Set’ button.

5. Press the ‘Set’ button once. You will see

the ‘Ø’ symbol flashing which represents

the Floor Temperature Limiter.

6. Using the ‘+’ or ‘–’ button, advance the

temperature to 30°C (maximum).

7. Press the ‘Set’ button once to return

to Normal Operating Mode.