2.3 Setting a data length
2.4 Setting a stop bit length
2.5 Setting a parity
2.6 Setting whether to conduct a BCC check
Operate the ▲ and ▼ keys to make the settings. The initial value is
H H H H
.
˜¿¢p
p: Stop bit length
F
Stop bit 1
I
Stop bit 2
¢: Parity
c
No parity
f
Odd parity
D
Even parity
¿: Data length
N
Data length, 7 bits
E
Data length, 8 bits
˜: BCC check
c
BCC check disabled
j
BCC check enabled
2.7 Setting a communications speed
Operate the ▲ and ▼ keys to make the settings. The initial value is
H H
.
****
I
1200 BPS
K
2400 BPS
E
4800 BPS
M
9600 BPS
2.8 Setting an address
Operate the ▲ and ▼ keys to make the settings. The initial value is
H
.
Setting range: 1 to 99 stations (It cannot be set to a 0.)
2.9 Setting a response delay time
Set a time from the time when the high-level computer finished sending a "request message" until
the time when it delivers the line and enters an input state.
Operate the ▲ and ▼ keys to make the settings. The initial value is ###.
Setting range: 0 to 250msec