EA3023 3A POWER SUPPLY CALIBRATION ADAPTER

OPERATION MANUAL

Transmille Ltd.

Page 10

Functions : Setting A Current Load


Use the on screen keyboard to set the required current load :

Press the ENTER button to preset the current load, then press

to apply the

setting– the applied load will be displayed on the power supply current meter – the
VFP will display

Use the

button to turn off the current load – the VFP will display

Functions : Output Resistance Measurement


The output resistance measurement function uses the electronic current load to
measure the voltage drop on-load and off-load. Using a calculation the output
resistance can then be displayed.

Press the output resistance measurement button - the virtual front
panel will display ‘Calculating…’ while the load is turned on, then off in
a controlled sequence to determine the voltage drop and calculating
the output resistance.


If no voltage drop is detected a message will be displayed to indicate the resistance
could not be determined.

Advertising