Trimec ES2000 Series Monitored Electric Strike User Manual

Installation instructions, Spare parts & accessories

Advertising
background image

IMPORTANT NOTE: Ensure any rebate strips or door stops are fi tted before proceeding.

For double-leaf doors, the inactive leaf must be securely fi xed in the closed position and a rebate strip fi tted to prevent
door over-travel.
Strike is suitable for 15mm latches, based on a 3mm door gap.

INSTALLATION INSTRUCTIONS

200/2000 SERIES ELECTRIC STRIKE

Mark positions X and Y of door latchbolt on door jamb (see Fig. 1).

Remove the backing of supplied stick-on template, and apply to door jamb. Ensure the lines “Front face of Lock Latch” on both template
and door jamb are aligned (see Note 1).

Scribe the door jamb according to template outline (see Fig. 2).

Prepare door jamb as per appropriate installation type; for Metal Jamb refer to Fig. 3, for Wood Jamb refer to Fig. 4. Install mounting tabs
where applicable. (see Note 2).

Ensure all wiring is correctly connected and not rubbing on sharp edges or interfering with any strike mechanism.

Install the strike temporarily in position and check there is no interference between the door, strike and lock face plates, and the extension
lip of strike during door closing. Ensure the deadlatching auxiliary bolt does not enter the strike keeper area when door is closed.

Check there is no pressure on the strike keeper when door is closed.

When all above checks are complete, secure strike with appropriate screws and re-check operation.

NOTE 1 : A 1mm clearance has been designed into the template to prevent the door exerting pressure on the strike when closed.
NOTE 2 : Allow suffi cient space between the electric strike unit and jamb cut-out for the wires. Bunching of wires may cause the unit
to malfunction.

1.

2.

3.

4.

5.

6.

7.

8.

Fig. 2 - 200/2000 Series Electric Strike Template Outline

Fig. 1 - Door Frame Preparation

Align with
“Front Face
of Lock
Latch” line
on Template

y

x

y

X

X

y

or

Bevelled Face

*These dimensions have a tolerance of +0.8mm/-0

161mm

Keeper Width

38mm

Limits of Extension Lip

100mm

*123mm

*176.21mm

*29mm

*44.5mm

Front Face of Lock Latch

NOT TO SCALE

Page 1

DRAWINGS NOT TO SCALE. INFORMATION IN THIS DATASHEET MAY BE CHANGED WITHOUT NOTICE.

Page 4

200/2000 SERIES

SPARE PARTS & ACCESSORIES

The following are available as optional extras:

SPARE PARTS

* When the use of extension lips is required, the standard model numbers of electric strikes must be suffi xed with “X” to denote
pre-drilled extension holes (e.g. 2000X).

25mm extension lip (A),

50mm extension lip (B)

75mm extension lip (C)

available as optional extras.

B

50mm

A

25mm

75mm

C

x

x

y

y

Door Edge

or

Mortice Lock

Tubular/Cylindrical

Latch

Part Number

Qty Per Pack

Description

220200-501

1

Solenoid Status Microswitch Assembly

220200-502

1

Door Latch Microswitch Assembly

220200-504

1 set

Screw Kit - Installation

220200-508

5 x (2 short, 1 long)

Locking Pins

220200-511

5

200 Series Locking Pin Return Spring

220200-520

5

Spring - Microswitch Retainer

220200-513

1

12 V Solenoid Coil

220200-514

1

24 V Solenoid Coil

220200-515

1

48 V Solenoid Coil

ACCESSORIES

Part Number

Qty Per Pack

Description

220200-519

1

Mounting Kit

220200-505

1

25mm Extension Lip *

220200-506

1

50mm Extension Lip *

220200-507

1

75mm Extension Lip *

5 Year Limited Warranty

ASSA ABLOY Australia guarantees for a period of 5 years in accordance with Trimec’s Standard Warranty Conditions, against defects in
manufacture, workmanship or materials, provided that all electrical and mechanical installation requirements are adhered to as per this
datasheet. All third party and consequential claims are expressly excluded from this warranty.

warranty

An ASSA ABLOY Group brand

DA0002, Issue 10: 25th July 2007

ASSA ABLOY Australia

2/16 Atkinson Road

Taren Point 2229

NSW, Australia

www.assaabloyasiapacifi c.com

Advertising
This manual is related to the following products: