Trimec ES2000 Series Monitored Electric Strike User Manual

Page 2

Advertising
background image

To change the electric strike’s mode of lock operation, remove the back cover and the 2 screws securing the solenoid.

Remove solenoid from strike housing, and invert the strike. This will release three locking pins from the strike and keeper chambers.
CAUTION! When removing solenoid, please be mindful to keep the plunger in the solenoid as it is not secured, and may be easily mis-
placed.

Re-insert the pins as shown in the diagrams for desired mode of lock operation (Power to Open: see Fig. 5; Power to Lock: see Fig. 6).

Place solenoid back in strike housing, and secure with solenoid screws. Press strike back cover into position.

1.

2.

3.

4.

Page 2

Page 3

Solenoid Leads Colour

Red

Blue

Black

Supply Voltage

12 VDC
24 VDC
48 VDC

Current Draw

175 mA

88 mA
45 mA

CAUTION!

Incorrect supply voltage may cause damage not covered by warranty. Please check supply voltage with a suitable meter

to ensure it is within +/- 15% of the nominal voltage shown above with the strike powered.

This product has been designed for use in weather protected areas only. DO NOT OIL OR LUBRICATE.

2000 Series Microswitch Monitoring

The 2000 Series electric strike is fi tted with a UL approved changeover microswitch (max. rating: 125 VAC, 3 A / 60 VDC, 200 mA) to monitor
the latch and strike status. The wiring diagram for the monitoring schematic is shown in Fig. 7 and on the back of the strike.

N.C. (Normally Closed)

Common

N.O. (Normally Open)

White

Orange

Grey

Strike

Common

N.O. (Normally Open)

Yellow

Violet

Brown

Latch

N.C. (Normally Closed)

Fig. 5 - Power To Open (Fail-Secure) Confi guration

Fig. 6 - Power To Lock (Fail-Safe) Confi guration

Certifi cation

AS4145.2 compliant

BS5872 approved

CE compliant

up to 4-hours fi re rating, depending on type of doorset
(in accordance with AS1905.1 - 1997, Part 1: Fire-resistant Doorsets)

Wiring methods and materials shall be in accordance with the National Electric Code, ANSI/NFPA 70 - 1996

Unit must be powered by a UL listed limited energy power source

Use only those mounting screws and hardware supplied with the product for installation. Do not use substitute installation fasteners or
hardware

UL listed for burglary resistance category 1034

Standard UL 1034 Tested and Listed for:

1,500 lbs. (680 kg) static strength rating

70 foot-lbs. dynamic strength rating

250,000 cycles endurance rating

At the request of ASSA ABLOY Australia, this model was tested to the following VOLUNTARY ratings:

1,000,000 cycles of operation

4

Hour

UL Listing

Solenoid

Plunger

Solenoid Leads

Strike Body

Locking Pins

(Long - Short - Short)

Pin Chamber

Locking Pins

(Short - Short - Long)

Solenoid

Plunger

Solenoid Leads

Strike Body

Pin Chamber

CHANGING MODE OF LOCK OPERATION

ELECTRICAL SPECIFICATIONS

Fig. 3 - Metal Jamb Installation

Fig. 4 - Wood Jamb Installation

Fig. 4 - Wood Jamb Installation

26mm

24mm

Fig. 7 - Monitoring Schematic

Fig. 7 - Monitoring Schematic

24mm

2400 series
strike shown